Works on this device
Bolt Tensile Calculator
Work out the load at which a bolt breaks, yields or reaches its proof load, from the tensile stress area of its metric or inch thread and the strengths of its class or grade. Find the allowable load with your safety factor, the tensile stress for a load, and the smallest thread in a list for a load.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the capacity of a bolt, the stress for a load, or the bolt size for a load.
- Choose the thread: an ISO metric thread with its diameter and pitch, a Unified inch thread with its diameter and threads per inch, or a stress area that you know.
- Type the tensile strength, and if you have them the yield strength and the proof stress of your bolt, from its standard or maker. The example menu fills the figures of some classes and grades for you to check.
- Add a safety factor for the allowable load. Choose Calculate.
The formulas
A property class such as 8.8 is read as 8 × 100 = 800 MPa nominal tensile strength and 0.8 × 800 = 640 MPa nominal yield strength. The standard gives the minimum values, which can be a little higher for some classes and sizes; use those.
- Load at a strength: F = S × As, with S the tensile strength Rm, the yield strength Re or the proof stress Sp, and As the tensile stress area. For n bolts that share the load evenly: n × S × As.
- Allowable load: Fa = S × As ÷ safety factor.
- Tensile stress: σ = F ÷ (n × As); safety factor = S ÷ σ.
- Area for a load: As = F × safety factor ÷ (n × S).
- Tensile stress area: ISO 898-1 As = (π/4) × (d − 0.938194 P)²; ASME B1.1 As = 0.7854 × (D − 0.9743 ÷ n)² in².
Worked example
An M12 × 1.75 bolt has a tensile stress area of 84.27 mm². With Rm = 800 MPa, Re = 640 MPa and Sp = 580 MPa it breaks at 67.41 kN, yields at 53.93 kN and has a proof load of 48.87 kN. With a safety factor of 2 on the yield load, one bolt may carry 26.97 kN.
A load of 40 kN on that bolt gives a tensile stress of 474.7 MPa: a safety factor of 1.35 against yield.
For 40 kN on one bolt with Re = 640 MPa and a safety factor of 2, the bolt needs a stress area of 125 mm². In the example list of metric coarse threads the smallest that has it is M16 × 2, with 156.7 mm². The strengths here are examples for trying the tool; check the figures of your own bolt.
Limits you should know
- This is ideal arithmetic for study and planning, not a design approval and not professional advice. The design must follow the code or standard that applies to your joint and be checked by a qualified engineer.
- Strengths are your figures. The example menu fills strengths of some ISO 898-1 classes and SAE J429 grades as remembered for this tool; check them in the standard, because they change with the size and the edition.
- The load is a pull along the bolt. Bending, fatigue, a short engagement in a soft nut and the share of the working load that a preloaded bolt takes are not worked out here.
- For the preload of a bolt and its clamp force, use the Bolt Preload Calculator. For bolts loaded across the shank, use the Bolt Shear Calculator. For thread sizes and the length of engagement, use the Screw Thread Calculator.