Toolvito

Works on this device

Base Plate Calculator

Work out a steel column base plate. Find the pressure under the plate for an axial load and a moment, the plate thickness by the cantilever method with the factors that you type, or the plate area for an allowable bearing pressure.

Enter your values

The pressure of a rigid base plate on the concrete or grout, for an axial load with or without a moment.

Your values

The compression from the column.

Bending along the length N of the plate. Type 0 for a centred load.

From the code for the concrete or grout under the plate. Not built in.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose the bearing pressure, the plate thickness or the plate area.
  2. Type the load, the plate size (N along the column depth or the moment, B across) and, for the pressure, the moment at the base.
  3. For the thickness, type the column depth and flange width, the factors of the method, the yield strength of the plate and your resistance or safety factor.
  4. Type an allowable bearing pressure from your code if you want to compare. Choose Calculate.

The formulas

  • Pressure, inside the kern (e = M ÷ P ≤ N ÷ 6): q = P ÷ (B N) × (1 ± 6 e ÷ N).
  • Pressure, outside the kern (N ÷ 6 < e < N ÷ 2), with no tension in the anchor rods: q_max = 2 P ÷ (3 B (N ÷ 2 − e)) on a contact length of 3 (N ÷ 2 − e).
  • Cantilevers (AISC Design Guide 1, 2nd edition, 2006, section 3.1): m = (N − c_d × d) ÷ 2, n = (B − c_b × b_f) ÷ 2, n' = √(d × b_f) ÷ 4, l = max(m, n, λ n'). The guide gives c_d = 0.95 and c_b = 0.8 for a wide-flange column; you type them.
  • Thickness: t = l × √(2 f_p ÷ (φ F_y)) for LRFD, or l × √(2 Ω f_p ÷ F_y) for ASD, with f_p = P ÷ (B N).
  • Plate area: A = P ÷ q.

Worked example

A plate 450 mm by 400 mm carries 600 kN and 30 kN·m. e = 30 ÷ 600 = 50 mm, inside the kern 450 ÷ 6 = 75 mm. The mean pressure is 600,000 ÷ (400 × 450) = 3.333 MPa, so q_max = 3.333 × (1 + 6 × 50 ÷ 450) = 5.556 MPa and q_min = 1.111 MPa. With 90 kN·m, e = 150 mm is outside the kern: 225 mm of the plate stays in contact and q_max = 13.33 MPa.

Under a column 310 mm deep with a 305 mm flange and P_u = 1,200 kN: m = (450 − 0.95 × 310) ÷ 2 = 77.75 mm, n = (400 − 0.8 × 305) ÷ 2 = 78 mm and n' = 76.87 mm, so l = 78 mm. f_p = 6.667 MPa and, with F_y = 250 MPa and φ = 0.9, t = 78 × √(2 × 6.667 ÷ (0.9 × 250)) = 18.99 mm. The strength and factors here are examples for trying the tool.

Limits you should know

  • The pressure takes a rigid plate and no tension in the anchor rods. When the load falls outside the plate, the anchor rods must pull; that case is not worked out. Codes and design guides also use other pressure methods.
  • The thickness method is for a centred load. For a plate with a moment you may type a larger bearing pressure under More options, as a cautious use of the method.
  • No steel grade, concrete bearing strength or factor is built in. The bearing strength of the concrete or grout, the anchor rods and the welds are not checked. For anchor bolts, see the Anchor Bolt Calculator; for the column load, the Column Load Calculator.
  • This is arithmetic for study and checking. It does not check a design: the engineer of record and the code in force decide. It is not professional advice.

Related tools