Toolvito

Works on this device

Column Buckling Calculator

Work out the load at which a column buckles, for short, intermediate and long columns. The page uses the Johnson parabola below the transition slenderness and Euler above it. It can also apply a named code column curve with the factors that you type.

Enter your values

The critical load of a column of any length: the Johnson parabola for intermediate columns, Euler for long ones.

Your values

Smaller than the outside diameter. The wall thickness is (D − di) ÷ 2.

Young's modulus of the material, from its data sheet, a handbook or your code. The example, 200 GPa, is a typical handbook figure for steel.

From the material standard, the data sheet or your code. The example is for trying the tool only.

The unbraced length: the distance between the points that hold the column against moving sideways.

Your own factor, or the one your code asks for. The critical load is divided by it.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Buckling load of a column (Euler or Johnson), or Code column curve for a steel design method.
  2. Choose the cross-section and type its sizes. For a rolled section, type A and the smaller I from a steel table.
  3. Type E, the yield strength, the length between supports, and choose the end conditions or type your own K.
  4. For a code curve, choose the code and type its factors from the code in force. Choose Calculate. The chart shows the column on the curves.

The formulas

  • Transition slenderness: Cc = √(2 × π² × E ÷ σy). At Cc both curves give σy ÷ 2.
  • Johnson parabola (K L ÷ r below Cc): σ_cr = σy − (σy² ÷ (4 π² E)) × (K L ÷ r)².
  • Euler (K L ÷ r at or above Cc): σ_cr = π² × E ÷ (K L ÷ r)². The critical load is P_cr = σ_cr × A.
  • EN 1993-1-1:2005, clause 6.3.1.2: N_cr = π² E I ÷ L_cr², λ̄ = √(A fy ÷ N_cr), Φ = 0.5 [1 + α (λ̄ − 0.2) + λ̄²], χ = 1 ÷ (Φ + √(Φ² − λ̄²)) ≤ 1, N_b,Rd = χ A fy ÷ γM1. You type α (the buckling curve) and γM1.
  • ANSI/AISC 360-16, section E3: Fe = π² E ÷ (Lc ÷ r)²; Fcr = 0.658^(Fy ÷ Fe) × Fy when Lc ÷ r ≤ 4.71 √(E ÷ Fy), else Fcr = 0.877 Fe; Pn = Fcr × Ag. You type φc (LRFD) or Ωc (ASD).

Worked example

A steel tube 100 mm outside and 90 mm inside, 3 m long and pinned at both ends: A = 1,492 mm², r = 33.63 mm and K L ÷ r = 89.2. With E = 200 GPa and σy = 250 MPa, Cc = 125.7, so the column is intermediate.

Johnson: σ_cr = 250 − 250² ÷ (4 π² × 200,000) × 89.2² = 187.0 MPa, and P_cr = 187.0 × 1,492 = 279.1 kN. Euler would give 248.1 MPa here, too high for a column this short.

With the Eurocode curve and α = 0.34, γM1 = 1.0: N_cr = 370.2 kN, λ̄ = 1.004, Φ = 1.140, χ = 0.5946 and N_b,Rd = 221.8 kN. With AISC E3 and φc = 0.9: Fe = 248.1 MPa, Fcr = 0.658^(250 ÷ 248.1) × 250 = 164.0 MPa, Pn = 244.7 kN and φc Pn = 220.2 kN. The material values and factors here are examples for trying the tool, not values to design with.

Limits you should know

  • Euler and Johnson take an ideal straight column with a centred load. Real columns carry less; that is why codes have their own curves.
  • No code factor, steel grade or section table is built in. The two code methods are named with their edition and clause so that you can check them; type the factors of the edition and National Annex in force.
  • The code methods cover flexural buckling about one axis of a steel member: class 1 to 3 sections (Eurocode) or sections without slender elements (AISC). Local, torsional and flexural-torsional buckling are not covered. Timber and concrete columns follow other rules.
  • For the slenderness ratio and column classes, use the Column Slenderness Calculator. For long columns alone, the Euler Buckling Calculator. For K, the Effective Length Calculator. For the load from the floors, the Column Load Calculator.
  • This is arithmetic for study and checking. It does not check a design: the engineer of record and the code in force decide. It is not professional advice.

Related tools