Toolvito

Works on this device

Column Slenderness Calculator

Find the slenderness ratio K L ÷ r of a column. Choose the section and the end conditions and type the length. Type E and the yield strength for the transition slenderness, and your own limits to class the column as short, intermediate or long.

Enter your values

The slenderness ratio K L ÷ r of a column, and its class against the limits that you type.

Your values

Smaller than the outside diameter. The wall thickness is (D − di) ÷ 2.

The unbraced length: the distance between the points that hold the column against moving sideways.

More options

Young's modulus of the material, from its data sheet, a handbook or your code. The example, 200 GPa, is a typical handbook figure for steel.

From the material standard, the data sheet or your code. The example is for trying the tool only.

The slenderness up to which your code or method treats a column as short (no buckling check). The example is only for trying the tool.

The highest K L ÷ r that your code or project allows for a compression member. The example is only for trying the tool.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Slenderness ratio of a column, the transition slenderness, or the longest length for a limit.
  2. Choose the cross-section and type its sizes. For a rolled section, type A and I from a steel table, or type the radius of gyration r.
  3. Type the length between supports and choose the end conditions, or type your own factor K.
  4. Under More options, type E and the yield strength, and the limits of your code or method, to class the column. Choose Calculate.

The formulas

  • Radius of gyration: r = √(I ÷ A), with I the second moment of area about the axis of buckling and A the area.
  • Slenderness ratio: λ = K × L ÷ r, with L the length between supports and K the effective length factor.
  • Transition slenderness: Cc = √(2 × π² × E ÷ σy). Below Cc a column buckles inelastically (the Johnson parabola); at and above Cc it buckles elastically (Euler). At Cc the critical stress is σy ÷ 2.
  • Class: short when λ is at or below the short-column limit that you type; intermediate when it is above that and below Cc; long (slender) at or above Cc.
  • Longest length for a limit: L = λ_max × r ÷ K.

Worked example

A steel tube 100 mm outside and 90 mm inside, 3 m long, both ends pinned (K = 1.0). r = √(I ÷ A) = √((100² + 90²) ÷ 16) = 33.63 mm, so λ = 3,000 ÷ 33.63 = 89.2.

With E = 200 GPa and σy = 250 MPa, Cc = √(2 × π² × 200,000 ÷ 250) = 125.7. The column is above a short-column limit of 40 and below Cc, so it is intermediate.

A rectangle 100 mm by 50 mm, 3 m long and pinned, has r = 50 ÷ √12 = 14.43 mm about its weak axis and λ = 207.8 (103.9 about the strong axis). For a limit of 200 the tube above may be at most 200 × 33.63 mm = 6.73 m long. The limits, E and σy here are examples, not values from a code.

Limits you should know

  • No code limit is built in. Steel, concrete and timber codes each set their own limits and classes; type the figures of the code in force.
  • For a rectangle the weak axis is used, and the strong axis is shown for comparison. For a typed section, type I or r about the axis on which the column can buckle.
  • A slenderness within the limits says nothing about the load. For the buckling load, use the Euler Buckling Calculator for long columns or the Column Buckling Calculator for all lengths. For K from the frame, use the Effective Length Calculator.
  • This is arithmetic for study and checking. It does not check a design: the engineer of record and the code in force decide. It is not professional advice.