Works on this device
Euler Buckling Calculator
Work out the load at which a slender column buckles sideways, by Euler’s formula. Choose the section and the end conditions, and type the length and the modulus of elasticity. You can also find the longest column for a load, or the second moment of area you need.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want: the critical load, the critical stress from a slenderness ratio, the longest column for a load, or the second moment of area needed.
- Choose the cross-section and type its sizes. For a rolled steel section, choose An area and a second moment of area that I type and copy A and the smaller I from a steel table.
- Type the modulus of elasticity E and the length between supports. Choose the end conditions, or type your own factor K.
- If you know the proportional limit of the material, type it: the page then says whether Euler’s formula applies. Choose Calculate.
The formula
- Critical load: P_cr = π² × E × I ÷ (K × L)², with E the modulus of elasticity, I the smaller second moment of area of the section, L the length between supports and K the effective length factor.
- Critical stress: σ_cr = P_cr ÷ A = π² × E ÷ (K L ÷ r)², with r = √(I ÷ A) the radius of gyration. K L ÷ r is the slenderness ratio.
- Limit of the formula: Euler holds while σ_cr is below the proportional limit σ_pl of the material, that is for K L ÷ r ≥ π × √(E ÷ σ_pl).
- Longest column for a load: L = π × √(E × I ÷ P) ÷ K. I needed: I = P × (K L)² ÷ (π² × E).
| End conditions | K in theory |
|---|---|
| Both ends pinned | 1.0 |
| Both ends fixed | 0.5 |
| One end fixed, the other pinned | 0.7 (0.6992 exactly) |
| One end fixed, the other free (a flagpole) | 2.0 |
| One end fixed, the other free to move sideways but not to turn | 1.0 |
| One end pinned, the other free to move sideways but not to turn | 2.0 |
These are the values of the theory. Real ends are never perfectly fixed, so design codes recommend larger design values where an end is fixed. Type the value of your code as your own K.
Worked example
A steel tube 100 mm outside and 90 mm inside, 4 m long with both ends pinned (K = 1.0). Its area is A = π × (100² − 90²) ÷ 4 = 1,492 mm², I = π × (100⁴ − 90⁴) ÷ 64 = 1,688,115 mm⁴ and r = 33.63 mm. The slenderness ratio is 4,000 ÷ 33.63 = 118.9.
With E = 200 GPa: P_cr = π² × 200,000 MPa × 1,688,115 mm⁴ ÷ (4,000 mm)² = 208.3 kN, and σ_cr = 208,263 N ÷ 1,492 mm² = 139.6 MPa. With a proportional limit of 200 MPa, Euler holds above a slenderness of π × √(200,000 ÷ 200) = 99.3, so it applies here.
The same tube under 50 kN buckles at K L = π × √(E I ÷ P) = 8.16 m. A column 3 m long with one end fixed and one pinned (K = 0.7) needs I = 50 kN × (2.1 m)² ÷ (π² × 200 GPa) = 111,707 mm⁴ for P_cr = 50 kN: a solid round bar of at least 38.84 mm. The figures for E and the proportional limit are examples, not values for your material.
Limits you should know
- Euler’s formula is for elastic buckling only: a straight, slender column, a load along its axis and a critical stress below the proportional limit. Shorter (intermediate) columns fail at lower loads: use the Column Buckling Calculator, which has the Johnson parabola and code column curves.
- Real columns have small bends and off-centre loads, so they carry less than P_cr. Design codes allow for this with their own column curves and safety factors. This page does not apply any code.
- For a rectangle the page uses the smaller second moment of area. For a typed section, type the I about the axis on which the column can buckle; check each axis with its own length and K.
- For the slenderness ratio and its classes, use the Column Slenderness Calculator. For K from the stiffness of the beams at the ends of a column (alignment charts), use the Effective Length Calculator. For the load that reaches a column from the floors, use the Column Load Calculator.
- This is arithmetic for study and checking. It does not check a design: the engineer of record and the code in force decide. It is not professional advice.