Structural Stability Worksheet
Work through the classic stability checks with your own numbers and see every formula: the buckling load and capacity of a column (Euler, with Johnson’s parabola for shorter columns), a whole schedule of columns, the overturning and sliding of a wall, footing or sign, dead and live loads on a tributary area with the ASCE 7 and EN 1990 combinations, and the self-weight of beams and columns. This is a worksheet to check by hand and to learn from, not a design or an approval.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose the button below them.
Your result
How it was worked out
How to use it
- Choose Column buckling, type E, I (about the weaker axis), A, the length and the end conditions, the load and, if you know it, the yield strength.
- Read the slenderness, the critical load and stress, the capacity and the factor of safety.
- Choose Overturning and sliding for a block on its base, Loads and combinations for floor loads, or Self-weight of members for the weight of the steel or concrete.
The formulas
- Euler: P_cr = π² E I ÷ (K L)²; slenderness λ = K L ÷ r, with r = √(I ÷ A).
- J. B. Johnson: σ_cr = f_y (1 − f_y λ² ÷ (4 π² E)) when Euler’s stress is above half the yield strength.
- Overturning: FS = W a ÷ (H h) about the toe; sliding: FS = μ W ÷ H; base pressure W ÷ B × (1 ± 6 e ÷ B) when the resultant is in the middle third.
- Combinations: 1.4 D and 1.2 D + 1.6 L (ASCE/SEI 7-22 §2.3.1), 1.35 G + 1.5 Q (EN 1990, equation 6.10).
Not a design
Building codes use their own buckling curves, imperfections, partial factors and many more checks (connections, local buckling, lateral-torsional buckling, foundations). Use these results to understand and to check, and have a qualified engineer design and approve any structure.