Find what size of water heater meets your hot water demand. For a tank heater, work out its first-hour delivery from the tank, the burner or element and the temperature rise; for a tankless heater, the power for your flow.

Enter your values

How much hot water a tank heater gives in a busy hour: the usable hot water in the tank plus what the burner or element heats in that hour.

Your values

Rough example: about 70%. Cold water comes in as hot water is drawn and mixes with it, so not all the tank comes out hot. Use the maker's figure when you have it.

The burner input on the label of a gas heater, or the element power of an electric one (in most electric tanks only one element heats at a time).

The share of the input that goes into the water, from the maker's data. Rough examples: a gas tank about 78%, electric elements about 98%, a heat pump water heater its COP × 100 (such as 300%).

It changes with the place and the season. For a design, take the coldest month.

The set temperature of the tank, or the outlet temperature of a tankless heater.

The hot water used in the busiest hour, at the tank temperature. The Hot Water Demand Calculator works it out.

More options

About 1000 kg/m³ for cold water and 983 kg/m³ at 60 °C (140 °F). For a glycol mix, type the figure of the maker.

About 4.186 kJ/(kg·K) (1 BTU/(lb·°F)) for water. Glycol mixes are lower: use the figure of the maker.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Work out your hot water demand first: the hot water in the busiest hour for a tank, or the flow of the taps that run together for a tankless heater. The Hot Water Demand Calculator does this from your fixtures.
  2. For a tank heater you have in mind, choose First-hour delivery. Type the tank size, the input power, the recovery efficiency and the two water temperatures. Add your peak-hour demand to check it.
  3. To size a tank, choose Tank size or heater power for a peak demand, and find the tank for a heater power or the power for a tank.
  4. For a tankless heater, choose Tankless, and find the power for a flow or the flow for a power.
  5. Choose Calculate. You get the results and the working.

The formulas

  • Temperature rise = hot water temperature − cold water temperature.
  • Recovery rate = input power × recovery efficiency ÷ (density × specific heat × rise). In US units, about BTU/h × efficiency ÷ (8.34 × °F) gallons per hour.
  • First-hour delivery = tank size × usable share + recovery rate × 1 hour.
  • Tank for a peak = (demand − recovery × length of the peak) ÷ usable share. Power for a peak = (demand − tank × usable share) × density × specific heat × rise ÷ length of the peak ÷ efficiency.
  • Tankless power = flow × density × specific heat × rise ÷ efficiency. In US units, about 500 × gpm × °F rise in BTU/h.

Worked example

A 50 gallon gas tank has a 40,000 BTU/h burner with a recovery efficiency of 78%. Cold water at 50 °F is heated to 120 °F, a rise of 70 °F. The recovery rate is 40,000 × 0.78 ÷ (8.34 × 70) = about 53.4 gallons per hour.

With 70% of the tank usable, the first-hour delivery is 50 × 0.7 + 53.4 = 88.4 gallons, enough for a peak hour of 60 gallons.

A tankless heater for 4 gpm at the same 70 °F rise must put 140,176 BTU/h into the water, so at 95% efficiency it needs an input of 147,554 BTU/h (43.2 kW).

Limits you should know

  • The usable share, the recovery efficiency and the starting figures are examples. Use the maker's data for the heater you have in mind.
  • The first-hour rating on a label comes from a standard test, not from this formula. When you have it, compare it with your peak-hour demand.
  • Use the coldest inlet temperature of the year. In winter the rise is larger, and a heater gives less hot water.
  • An electric tankless heater draws a large current. Its wires and breaker follow the maker's instructions and the electrical code.
  • For the running cost, or the energy and time to heat a tank of water, use the Water Heating Savings Calculator.
  • This is an estimate from your figures, not a design. The size of a water heater for a real building is set by the maker's data and the plumbing code or design method used where you live. This is not professional advice.