Water Turbidity Converter

Convert a turbidity reading between NTU, FNU, FTU, FAU and JTU, and learn what each unit means. To turn turbidity into suspended solids (TSS), fit a line to pairs of results from your own water, or use a line you already have.

Enter your values

Convert a turbidity reading between NTU, FNU, FTU, FAU and JTU, with what each unit means.

Your values

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose the button below them.

How to use this converter

  1. To change units, choose Convert between turbidity units, type the reading and choose its unit.
  2. To get suspended solids, choose Turbidity to suspended solids from your own pairs and type pairs of turbidity and TSS measured on the same samples. Type a turbidity to convert with the fitted line.
  3. If a report or a site study already gives a line for your water, choose Turbidity to suspended solids with a line you have and type its slope and intercept.
  4. The pairs and the line start empty. Try an example fills in made-up figures.

The units

NTU, FNU, FTU and FAU are all set by the formazin standard: a formazin suspension of a given strength has the same number in each unit. So the conversion is 1 to 1 by definition: 12.5 NTU of formazin is 12.5 FNU.

The meters see light in different ways, so real samples with colour or large particles can read differently in NTU and in FNU. A result for a report or a permit must be measured by the method the rule names. JTU readings agree with formazin units only roughly.

Turbidity units and what they measure
Unit Light and angle Standard or origin
NTU, nephelometric turbidity unit White light (a tungsten lamp), light scattered at 90° US EPA Method 180.1
FNU, formazin nephelometric unit Infrared light (860 nm), light scattered at 90° ISO 7027
FTU, formazin turbidity unit Any meter set with formazin An older general name for a formazin unit
FAU, formazin attenuation unit Infrared light (860 nm) that passes straight through ISO 7027 (attenuation)
JTU, Jackson turbidity unit A candle seen through a column of the sample The Jackson candle turbidimeter, an older visual method

Turbidity and suspended solids

There is no fixed factor between turbidity and suspended solids (TSS, in mg/L): it depends on the size, shape and colour of the particles, and it changes from water to water and season to season. So this converter fits a straight line to pairs measured on your own water, by least squares: TSS = a × turbidity + b, with a = Sxy ÷ Sxx and b = mean TSS − a × mean turbidity. Through zero, a = Σ(turbidity × TSS) ÷ Σ(turbidity²).

Worked example with the made-up pairs of Try an example (2, 5, 10, 20 and 40 NTU against 5.1, 11.8, 22.5, 47 and 91.5 mg/L): a = 2.28429, b = 0.40197, R² = 0.9997. At 15 NTU the line gives 2.28429 × 15 + 0.40197 = 34.67 mg/L, and 30 mg/L is 12.96 NTU. With a line of a = 2.3 and b = 0.4 (example), 15 NTU is 34.9 mg/L.

Limits you should know

  • No factor between turbidity and suspended solids is built in. Use a line only for the water it was fitted to, and within the range of its pairs.
  • A converted number does not replace a measurement by the method a rule names. Limits for turbidity and suspended solids differ by place and use; local rules decide.
  • Brewing haze units (EBC, ASBC) and the old silica scale are not covered.
  • For other water quality units, see the Pollutant Concentration Converter. To combine many results into one index, see the Water Quality Index Calculator.