Water Quality Index Calculator
Sum up many water test results in one index number by a named method: the weighted arithmetic index, the index of the Canadian Council of Ministers of the Environment (CCME), or the NSF index. You type the standards, objectives or sub-index values; the method is named in every result.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the method that your study, agency or class uses.
- Weighted arithmetic index: type each parameter with its measured value, its standard and its ideal value, in the same unit.
- CCME WQI: type each variable with its objective (an upper limit, a lower limit or a range) and all its results of the period.
- NSF WQI: read the Q value (0 to 100) of each parameter from the published NSF curves for your result, and type it.
- Standards, objectives and Q values start empty. Try an example fills in example values that are not the current limits of any authority.
The formulas
- Weighted arithmetic index (Brown et al., 1972): quality rating q = 100 × |V − Vi| ÷ |S − Vi| with the measured value V, the standard S and the ideal value Vi (0 for most parameters; 7 for pH and 14.6 mg/L for dissolved oxygen are often used). Unit weight W = K ÷ S with K = 1 ÷ Σ(1 ÷ S). WQI = Σ(q × W) ÷ Σ W.
- CCME WQI (2001): F1 = failed variables ÷ all variables × 100; F2 = failed tests ÷ all tests × 100; excursion = result ÷ objective − 1 above an upper objective, or objective ÷ result − 1 below a lower one; nse = Σ excursions ÷ all tests; F3 = nse ÷ (0.01 nse + 0.01); WQI = 100 − √(F1² + F2² + F3²) ÷ 1.732.
- NSF WQI (Brown et al., 1970): WQI = Σ(w × Q) ÷ Σ w, with the weights dissolved oxygen 0.17, fecal coliform 0.16, pH 0.11, BOD 0.11, temperature change 0.10, total phosphate 0.10, nitrates 0.10, turbidity 0.08 and total solids 0.07.
The scales printed with each method
| Method | Best class | Second class | Third class | Fourth class | Worst class |
|---|---|---|---|---|---|
| Weighted arithmetic (lower is better) | 0 to 25: excellent | above 25 to 50: good | above 50 to 75: poor | above 75 to 100: very poor | above 100: unsuitable for drinking |
| CCME (higher is better) | 95 to 100: excellent | 80 to below 95: good | 65 to below 80: fair | 45 to below 65: marginal | below 45: poor |
| NSF (higher is better) | above 90: excellent | above 70 to 90: good | above 50 to 70: medium | above 25 to 50: bad | 0 to 25: very bad |
Worked examples
Weighted arithmetic, with the example values: pH 7.8 against 8.5 (ideal 7) gives q = 100 × 0.8 ÷ 1.5 = 53.3; dissolved oxygen 6.2 mg/L against 5 (ideal 14.6) gives q = 100 × 8.4 ÷ 9.6 = 87.5. With turbidity, dissolved solids, nitrate and hardness as well, the index is 67.98, "poor" on the printed scale. Dissolved oxygen is 47.2% of it, because its low standard gives it a high weight.
CCME, with the example objectives and 6 results for each of 4 variables: 3 of 4 variables and 5 of 24 tests fail, so F1 = 75 and F2 = 20.83. The excursions add up to 0.3763, so nse = 0.01568 and F3 = 1.54. The index is 55.0, "marginal".
NSF, with the example Q values: 0.17 × 85 + 0.16 × 40 + 0.11 × 90 + 0.11 × 70 + 0.10 × 85 + 0.10 × 60 + 0.10 × 95 + 0.08 × 75 + 0.07 × 80 = 74.05, "good".
Limits you should know
- Indices made by different methods, standards or weights give different numbers for the same water. Compare only results made in the same way.
- An index is not a safety verdict. Whether water is safe to drink or use is decided by each result against the limits in force where you are. Local rules decide.
- No standard, objective or NSF curve is built in. Take the standards from the rules you follow and the Q values from the published NSF curves.
- Type each value and its standard in the same unit. To change units first, use the Pollutant Concentration Converter.
- The CCME method asks for at least 4 variables sampled at least 4 times. Results below a detection limit must be given a value before they are typed.