Works on this device
Charge Balance Calculator
Enter the ions of a water analysis with their charges and concentrations. The calculator turns each one into milliequivalents per litre, adds the cations and the anions, and gives the ion balance error.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Ion balance of a water analysis.
- Add one row for each ion: its formula (such as
Ca,HCO3orSO4), its charge (such as2or-1), the concentration and its unit. - For alkalinity or hardness reported "as CaCO3", choose the unit mg/L as CaCO3.
- Choose Calculate. The table shows each ion in mmol/L and meq/L, and the result gives the sums and the error.
The formulas
- mmol/L = (mg/L) ÷ molar mass in g/mol. The molar mass comes from the formula.
- meq/L = mmol/L × the size of the charge. 1 mmol/L of Ca 2+ is 2 meq/L.
- mg/L as CaCO3 to meq/L: divide by 50.043, half the molar mass of CaCO3 (100.086 g/mol), because CaCO3 carries two charges.
- Ion balance error (%) = (Σ cations − Σ anions) ÷ (Σ cations + Σ anions) × 100, with both sums in meq/L. This is the form used in water analysis, for example in Standard Methods 1030 E.
- One ion by difference: the meq/L that makes the two sums equal, ÷ its charge, × its molar mass.
Worked example
The example rows are made-up values. Calcium 40 mg/L ÷ 40.078 = 0.998 mmol/L, × 2 = 1.99611 meq/L. Adding all cations gives 3.76566 meq/L; all anions give 4.21812 meq/L.
Error = (3.76566 − 4.21812) ÷ (3.76566 + 4.21812) × 100 = −5.67 %. There are more anions than cations, so a cation may be missing or an anion may be too high.
Without the sodium and nitrate rows, the anions are 1.24177 meq/L higher than the cations. Sodium by difference is then 1.24177 mmol/L, × 22.990 = 28.5482 mg/L.
Limits you should know
- The concentrations and charges are your input. The example rows are for trying the tool and are not a real analysis.
- Write a charge in the charge box, or in the formula after ^ or a space (
SO4^2-,Ca 2+). If you typeHCO3-, the charge box decides how to read it. - mg/L and ppm are the same for dilute water. For other liquids, use mmol/L or meq/L.
- The tool does not decide whether a result is acceptable. Your laboratory method states the accepted error; you can type it to compare.