Toolvito

Works on this device

Thermistor Calculator

An NTC thermistor is a resistor whose resistance falls as it gets warmer. This calculator converts between its resistance and its temperature with the Beta equation or the Steinhart-Hart equation, finds the B value or the Steinhart-Hart coefficients from measured points, and makes a resistance table.

Enter your values

The common way to describe an NTC thermistor: its resistance R0 at T0 (often 10 kΩ at 25 °C) and its B value.

Your values

The nominal resistance from the data sheet, for example 10 kΩ for a "10k" thermistor. It is usually given at 25 °C.

The B constant from the data sheet, often written B25/50 or B25/85. 3950 K is only an example.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose the equation. The Beta equation needs R0, T0 and the B value from the data sheet. The Steinhart-Hart equation needs the coefficients A, B and C.
  2. Choose the direction: the resistance at a temperature, or the temperature from a measured resistance.
  3. If the data sheet gives a table instead, use two points to get the B value, or three points to get A, B and C. The button Use these coefficients copies them into the Steinhart-Hart option.
  4. For a printed-style table and a curve, choose Resistance table and curve.

The thermistor equations

  • Beta equation: R = R0 × e^(B × (1/T − 1/T0)), and back: 1/T = 1/T0 + ln(R ÷ R0) ÷ B. T and T0 are in kelvin (°C + 273.15).
  • B value from two points: B = ln(R1 ÷ R2) ÷ (1/T1 − 1/T2). Data sheets name it by the two temperatures, such as B25/85.
  • Steinhart-Hart equation: 1/T = A + B × ln R + C × (ln R)³, with R in ohms.
  • Resistance from temperature (Steinhart-Hart): the equation is a cubic in ln R. With B and C above 0 it has one real root, which Cardano's formula gives.
  • A, B and C from three points: the three equations are solved together.
  • Temperature coefficient: α = −B ÷ T², the change for 1 kelvin as a share of the resistance.

Worked examples

A 10 kΩ thermistor with B = 3950 K at 50 °C: T = 323.15 K and T0 = 298.15 K. R = 10,000 × e^(3950 × (1/323.15 − 1/298.15)) = 3,588 Ω. Its coefficient there is −3.78% per kelvin.

The same thermistor reads 5 kΩ: 1/T = 1/298.15 + ln(0.5) ÷ 3950, so T = 314.61 K = 41.46 °C.

B value from a table: 10 kΩ at 25 °C and 1.087 kΩ at 85 °C give B = ln(10 ÷ 1.087) ÷ (1/298.15 − 1/358.15) = 3,949 K.

Limits you should know

  • No thermistor data is built in. R0, B and A, B, C come from the data sheet of your part; the values in the boxes are only examples.
  • The Beta equation is close near T0 and over a few tens of degrees. Over a wide range the Steinhart-Hart equation fits a real part better.
  • These equations are for NTC thermistors. PTC thermistors that switch at a set temperature follow their maker's table instead and are not covered.
  • The measuring current warms the thermistor (self-heating), so keep it as small as the data sheet asks.
  • To read a thermistor in a voltage divider, work out its resistance first with the Voltage Divider Calculator. For platinum sensors, use the Rtd Resistance Calculator.