Works on this device
Thermistor Calculator
An NTC thermistor is a resistor whose resistance falls as it gets warmer. This calculator converts between its resistance and its temperature with the Beta equation or the Steinhart-Hart equation, finds the B value or the Steinhart-Hart coefficients from measured points, and makes a resistance table.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the equation. The Beta equation needs R0, T0 and the B value from the data sheet. The Steinhart-Hart equation needs the coefficients A, B and C.
- Choose the direction: the resistance at a temperature, or the temperature from a measured resistance.
- If the data sheet gives a table instead, use two points to get the B value, or three points to get A, B and C. The button Use these coefficients copies them into the Steinhart-Hart option.
- For a printed-style table and a curve, choose Resistance table and curve.
The thermistor equations
- Beta equation: R = R0 × e^(B × (1/T − 1/T0)), and back: 1/T = 1/T0 + ln(R ÷ R0) ÷ B. T and T0 are in kelvin (°C + 273.15).
- B value from two points: B = ln(R1 ÷ R2) ÷ (1/T1 − 1/T2). Data sheets name it by the two temperatures, such as B25/85.
- Steinhart-Hart equation: 1/T = A + B × ln R + C × (ln R)³, with R in ohms.
- Resistance from temperature (Steinhart-Hart): the equation is a cubic in ln R. With B and C above 0 it has one real root, which Cardano's formula gives.
- A, B and C from three points: the three equations are solved together.
- Temperature coefficient: α = −B ÷ T², the change for 1 kelvin as a share of the resistance.
Worked examples
A 10 kΩ thermistor with B = 3950 K at 50 °C: T = 323.15 K and T0 = 298.15 K. R = 10,000 × e^(3950 × (1/323.15 − 1/298.15)) = 3,588 Ω. Its coefficient there is −3.78% per kelvin.
The same thermistor reads 5 kΩ: 1/T = 1/298.15 + ln(0.5) ÷ 3950, so T = 314.61 K = 41.46 °C.
B value from a table: 10 kΩ at 25 °C and 1.087 kΩ at 85 °C give B = ln(10 ÷ 1.087) ÷ (1/298.15 − 1/358.15) = 3,949 K.
Limits you should know
- No thermistor data is built in. R0, B and A, B, C come from the data sheet of your part; the values in the boxes are only examples.
- The Beta equation is close near T0 and over a few tens of degrees. Over a wide range the Steinhart-Hart equation fits a real part better.
- These equations are for NTC thermistors. PTC thermistors that switch at a set temperature follow their maker's table instead and are not covered.
- The measuring current warms the thermistor (self-heating), so keep it as small as the data sheet asks.
- To read a thermistor in a voltage divider, work out its resistance first with the Voltage Divider Calculator. For platinum sensors, use the Rtd Resistance Calculator.