Works on this device
Rtd Resistance Calculator
An RTD (resistance temperature detector) is a sensor whose resistance rises with temperature. This calculator converts between the temperature and the resistance of Pt100, Pt1000 and other platinum RTDs, makes a resistance table, and handles sensors described by one coefficient α, such as copper RTDs.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the direction: resistance from temperature, temperature from resistance, or a table.
- Choose the sensor: Pt100 (100 Ω at 0 °C), Pt1000 (1000 Ω at 0 °C), or another platinum sensor with its own R0.
- Enter the temperature or the measured resistance and pick the unit.
- The standard IEC 60751 coefficients are used. Under More options you can type your own A, B and C from a data sheet.
- For a copper, nickel or other sensor given by one coefficient α, choose Straight-line RTD.
The Callendar-Van Dusen equation
IEC 60751 gives the resistance of an industrial platinum RTD at a temperature t in °C as:
- From 0 °C to 850 °C: R(t) = R0 × (1 + A × t + B × t²).
- From −200 °C to 0 °C: R(t) = R0 × (1 + A × t + B × t² + C × (t − 100) × t³).
- A = 3.9083 × 10⁻³ per °C, B = −5.775 × 10⁻⁷ per °C², C = −4.183 × 10⁻¹² per °C⁴.
- These give R(100 °C) ÷ R(0 °C) = 1.385055, which is why the curve is called α = 0.00385.
- Temperature from resistance, at 0 °C and above: t = (−A + √(A² − 4B × (1 − R ÷ R0))) ÷ (2B). This is the root of the quadratic that lies in the range; the other root, near 6,700 °C, has no meaning.
- Below 0 °C the equation has the fourth power of t, so the tool finds the temperature between −200 °C and 0 °C by halving the interval, where the curve rises steadily and has one root.
- Straight-line model: R = R0 × (1 + α × (t − t0)), and α = (R2 − R0) ÷ (R0 × (t2 − t0)) from two readings.
Worked examples
Pt100 at 100 °C: R = 100 × (1 + 0.39083 − 0.005775) = 138.5055 Ω. At this point the resistance rises by 0.3793 Ω for each degree.
Pt100 at −100 °C: R = 100 × (1 − 0.39083 − 0.005775 − 0.0008366) = 60.2558 Ω.
Pt1000 at 25 °C: R = 1000 × (1 + 0.0977075 − 0.000360938) = 1097.347 Ω.
A Pt100 reads 109.73 Ω: R ÷ R0 = 1.0973, so t = (−A + √(A² − 4B × (1 − 1.0973))) ÷ (2B) = 24.988 °C.
Limits you should know
- The equation covers −200 °C to 850 °C. Outside that range the tool gives no answer.
- This is the ideal curve. A real sensor differs by its tolerance class, which the data sheet states.
- With 2 wires, the resistance of the leads adds to the reading and makes the temperature look higher. A 3-wire or 4-wire connection removes most of that.
- The measuring current warms the sensor a little (self-heating).
- No sensor data is built in other than the IEC 60751 coefficients. A copper or nickel sensor needs its α from the data sheet.
- For NTC and PTC thermistors, use the Thermistor Calculator.