Toolvito

Works on this device

Measurement System Analysis Calculator

Find out how much of the variation in your measurements comes from the gauge and the people who use it. Paste the readings of a gauge R&R study, with parts, operators and repeated trials, and choose the method.

Enter your values

The method of the standard GRR form: it uses the ranges of the trials and the ranges of the means.

Your values

Upper limit minus lower limit, in the unit of the readings. If you give it, the results are also shown as a percentage of the tolerance.

Readings of the study

One row for each reading: the part, the operator and the value. Every operator must measure every part the same number of times (at least twice).

One line for each part and operator: the part, the operator, then the readings of that operator on that part, such as 1, A, 10.02, 10.03. Lines copied from a spreadsheet, with a tab between the cells, also work. One reading on a line is fine too.

More options

It is used for the study variation column and for the percentage of the tolerance. The 4th edition of the AIAG manual uses 6. Earlier editions used 5.15.

The standard form uses one value of K1 for each number of trials. The second choice uses d2* for the true number of ranges (parts × operators), which matters only for a small study.

A guideline of the AIAG manual, not a law. Change it to the rule of your own quality system.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Plan the study: several parts that cover the spread of the process, two or more operators, and two or more trials of every part by every operator. Ten parts, three operators and three trials is a common plan.
  2. Choose Gauge R&R by the average and range method or Gauge R&R by the ANOVA method.
  3. Type one row for each reading: the part, the operator and the value. You can also paste the study and choose Read into rows. A pasted line holds the part, the operator and then the trials, such as 1, A, 10.02, 10.03.
  4. Give the width of the tolerance if you want the results as a percentage of the tolerance.
  5. Choose Calculate. The tables can be downloaded as a CSV file.

What the results mean

  • Repeatability (EV): the scatter when the same operator measures the same part again. It comes from the equipment.
  • Reproducibility (AV): the scatter between the averages of the operators. It comes from how different people use the gauge.
  • Gauge R&R (GRR) = √(EV² + AV²). With the ANOVA method it also holds the interaction of parts and operators.
  • Part variation (PV): the true differences between the parts of the study.
  • Total variation (TV) = √(GRR² + PV²).
  • Percentage of the total variation = 100 × GRR ÷ TV. Percentage of the tolerance = 100 × 6 × GRR ÷ width of the tolerance.
  • Number of distinct categories (ndc) = 1.41 × PV ÷ GRR, rounded down.
  • All of these are standard deviations, in the unit of the readings.

The two methods

  • Average and range method. EV = R̄ × K1, where R̄ is the average range of the trials. AV = √((X̄diff × K2)² − EV² ÷ (parts × trials)), where X̄diff is the range of the operator averages. PV = Rp × K3, where Rp is the range of the part averages.
  • The constants K1, K2 and K3 are 1 ÷ d2*. This page works d2* out from the range of normal samples, and shows the constants it used so that you can compare them with your form. For 3 trials K1 is 0.5908, for 3 operators K2 is 0.5231, and for 10 parts K3 is 0.3146.
  • ANOVA method. A two-way analysis of variance splits the sum of squares into parts, operators, their interaction and repeatability. The variance of each source comes from the mean squares. The interaction is removed and pooled into repeatability when its p-value is above 0.05, a limit you can change under More options.
  • The two methods give close but not equal results. The ANOVA method uses every reading and can show an interaction.

Worked example

Five parts are measured twice each by operators A and B, with the readings that the page shows when it opens. The average range of the trials is R̄ = 0.009 mm, and for 2 trials K1 = 0.8862, so EV = 0.009 × 0.8862 = 0.00798 mm.

The operator averages are 10.027 and 10.040 mm, so X̄diff = 0.013 mm. With K2 = 0.7071: AV = √((0.013 × 0.7071)² − 0.00798² ÷ (5 × 2)) = 0.00884 mm. GRR = √(0.00798² + 0.00884²) = 0.01191 mm.

The part averages run from 9.960 to 10.115 mm, so Rp = 0.155 mm. With K3 = 0.4030 for 5 parts: PV = 0.155 × 0.4030 = 0.06247 mm, and TV = √(0.01191² + 0.06247²) = 0.06359 mm.

GRR is 18.72% of the total variation, and ndc = 1.41 × 0.06247 ÷ 0.01191 = 7.4, which rounds down to 7. For a tolerance of 0.5 mm, 6 × 0.01191 ÷ 0.5 = 14.29% of the tolerance.

Limits you should know

  • The study must be balanced: every operator measures every part the same number of times. The page does not handle missing readings or nested studies.
  • The limits of 10% and 30% and the 5 distinct categories are a guideline of the AIAG Measurement Systems Analysis manual. They are not a law, and you can change the limits under More options.
  • The percentages of the total variation depend on the parts you chose. If the parts do not cover the real spread of the process, use the percentage of the tolerance.
  • The average and range method on the standard form uses a K1 that is meant for more than 15 ranges. For a small study you can switch to the exact constant under More options.
  • The F tests assume readings that are roughly normal, with the same scatter for every part and operator.
  • Bias and linearity are in the Measurement Bias Calculator. Attribute (pass or fail) gauge studies and stability charts are not on this page.
  • The result guides a quality decision. Your customer requirement and your quality system decide.