Works on this device
RF Attenuator Calculator
Work out the resistors of an attenuator pad for a loss in decibels: Pi, T and bridged-T pads, pads between two different impedances, the minimum-loss pad and the resistive splitter. Each design shows the nearest standard resistor values and the loss and match they give.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the kind of pad, for example Pi pad attenuator.
- Type the attenuation in dB and the impedances at the two ends, such as 50 Ω and 50 Ω.
- Choose the series of standard resistors you buy from, such as E24 (5% parts) or E96 (1% parts). Type an input power if you want the power in each resistor.
- Choose Calculate. The result shows the exact resistor values, the nearest standard values and the loss and match those give.
The formulas
K = 10^(A ÷ 20) is the voltage ratio of a loss of A dB in a matched pad. N = K² is its power ratio.
- Pi pad, equal impedances Z0: each shunt resistor = Z0 × (K + 1) ÷ (K − 1); series resistor = Z0 × (K² − 1) ÷ (2K).
- T pad, equal impedances Z0: each series resistor = Z0 × (K − 1) ÷ (K + 1); shunt resistor = 2 × Z0 × K ÷ (K² − 1).
- Between Z1 and Z2: the T pad has shunt = 2√(N Z1 Z2) ÷ (N − 1) and series = Z1 (N + 1) ÷ (N − 1) − shunt (and the same with Z2). The Pi pad has series = (N − 1) ÷ 2 × √(Z1 Z2 ÷ N) and shunt = 1 ÷ ((N + 1) ÷ (Z1 (N − 1)) − 1 ÷ series).
- Least loss between Z1 and Z2 (Z1 larger): 20 × log10(√r + √(r − 1)) with r = Z1 ÷ Z2. The L pad gives it with series √(Z1 (Z1 − Z2)) and shunt Z2 √(Z1 ÷ (Z1 − Z2)).
- Bridged T: two series arms of Z0, a bridge of Z0 (K − 1) and a shunt of Z0 ÷ (K − 1).
- Star splitter with n outputs: n + 1 resistors of Z0 (n − 1) ÷ (n + 1). The loss from any port to any other is 20 × log10(n) dB.
- Balanced lines: an O pad is a Pi pad and an H pad is a T pad with each series resistor split into two halves, one in each wire.
Worked examples
- A 10 dB Pi pad for 50 Ω: K = 3.16228, shunt = 50 × 4.16228 ÷ 2.16228 = 96.248 Ω, series = 50 × 9 ÷ 6.32456 = 71.151 Ω. With E24 parts of 100 Ω and 68 Ω the pad gives 9.6289 dB and an input impedance of 50.331 Ω (return loss 49.63 dB).
- A 10 dB T pad from 75 Ω to 50 Ω: series 48.634 Ω at the 75 Ω side, shunt 43.033 Ω, series 18.078 Ω at the 50 Ω side. A pad between these impedances cannot lose less than 5.7195 dB.
- A two-way star splitter for 50 Ω uses three resistors of 16.667 Ω. Each output gets a quarter of the input power, 6.0206 dB less.
Limits you should know
- The formulas take ideal resistors and resistive (real) impedances at both ends. At high frequencies the resistors and the layout add inductance and capacitance; use non-inductive parts and keep leads short.
- Each resistor must take its share of the power as heat. Type the input power to see it, and choose parts with a margin.
- The loss of a coaxial cable is a different question: use the Coax Cable Loss Calculator. To turn any ratio into decibels, use the Decibel Calculator. For return loss and VSWR, use the VSWR & Return Loss Calculator. A plain voltage divider is in the Voltage Divider Calculator.
- This result is arithmetic on the values you typed. It is not professional engineering advice.