Find how many decibels of signal a run of coaxial cable loses, and how much power reaches the far end. Select a standard LMR cable or enter attenuation from your own cable data sheet. The calculator scales it to the length of your run and adds the connectors.

Enter your values

Use this for the loss of a length of coax, with its connectors, and the power left at the far end.

Your values

Read it from the data sheet of your cable, at your frequency or one near it.

Type it only when it differs from the frequency of the data-sheet value. The attenuation is then scaled by the square-root rule.

You can also type feet and inches, such as 75 ft 6 in.

From the data sheet of the connectors. Leave it empty to leave connectors out.

Type it to see the power that reaches the far end.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. For standard 50 Ω LMR-195, LMR-240 or LMR-400, choose Standard LMR cable loss, select the cable and enter the operating frequency (30 MHz to 8 GHz).
  2. For a cable with a known attenuation, choose Loss of a cable run.
  3. Read the attenuation of your cable from its data sheet at your frequency, for example "dB per 100 ft at 150 MHz", and type it with its basis.
  4. If the data sheet has no value at your frequency, type your frequency and the frequency of the data-sheet value. The calculator then scales it by the square-root rule.
  5. Type the cable length, and the loss of each connector if you want them counted. Type the power into the cable to see the power at the far end.
  6. Choose Calculate.

The formulas

  • Cable loss (dB) = attenuation per length × length. 1 dB per 100 ft is 3.2808 dB per 100 m.
  • Total loss = cable loss + number of connectors × loss of each connector.
  • Power at the far end = power in × 10^(−total loss ÷ 10). 3 dB of loss leaves about half of the power, 10 dB leaves a tenth.
  • Another frequency: α(f2) = α(f1) × √(f2 ÷ f1). This square-root rule covers the loss in the conductors only.
  • Standard LMR uses (K1 × √f + K2 × f) dB per 100 ft, with f in MHz. The two coefficients come from the standard cable sections in the [Times Microwave Systems Complete LMR Guide](https://timesmicrowave.com/wp-content/uploads/2024/04/lmr-complete-guide.pdf).
  • Longest cable = (allowed loss − connector loss) ÷ attenuation per length.

Worked examples

  • A cable with 6.6 dB per 100 ft, 100 ft long, loses 6.6 dB: 10^(−0.66) = 21.9% of the power reaches the far end.
  • A cable with 2.2 dB per 100 ft, 50 ft long, with four connectors of 0.15 dB each: 1.1 + 0.6 = 1.7 dB. Of 100 W in, 67.608 W reaches the far end (48.3 dBm).
  • A data sheet value of 10 dB per 100 m at 100 MHz, used at 400 MHz: 10 × √4 = 20 dB per 100 m by the square-root rule, so 30 m loses 6 dB.
  • With 6.6 dB per 100 ft and 3 dB allowed, the longest cable is 3 ÷ 6.6 × 100 = 45.455 ft (13.855 m).

Limits you should know

  • Use your supplier’s data for RG, Heliax, UltraFlex, 75 Ω cable and other variants. The three standard LMR models estimate typical matched cable performance.
  • The square-root rule leaves out the loss in the insulation, which grows faster with frequency. Above a few hundred MHz it gives too little loss. A data-sheet value at your own frequency is better.
  • The loss is for a cable ended in its own impedance. A high SWR adds loss: see the VSWR & Return Loss Calculator. Old, wet or sharply bent cable loses more.
  • For the voltage drop of power cables (12 V, DC or mains), use the Voltage Drop Calculator. For a cable cut to a number of wavelengths, see the RF Cable Length Calculator. For a whole radio link, see the Link Budget Calculator.