Find the length of coax or another line for a quarter wave, a half wave or any phase at a frequency, using the velocity factor of the cable. You can also find the electrical length and delay of a cable you have, a length or a fault from a TDR time, and the branch lengths of a phasing harness.

Enter your values

Use this to cut a cable to a quarter wave, a half wave or any phase at a frequency, such as a matching section or a stub.

Your values

From the data sheet. About 0.66 for solid polyethylene, 0.8 to 0.88 for foam, 1 for air.

You can type a fraction such as 1/4, 1/2 or 3/4, or a decimal.

Type it to get the shortest cable of the same phase (plus whole wavelengths) that reaches. You can type feet and inches.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to work out, for example Cable length for a phase or a fraction of a wavelength.
  2. Type the frequency and the velocity factor of your cable from its data sheet.
  3. Type the fraction of a wavelength (such as 1/4) or the phase in degrees. To make the cable long enough to reach, type the shortest length you need.
  4. Choose Calculate. Cut the cable a little long and trim it while you measure, because the velocity factor varies between batches.

The formulas

  • Wavelength in the cable: λc = VF × c ÷ f, with c = 299,792,458 m/s and VF the velocity factor.
  • Physical length for a fraction n of a wavelength: L = n × λc. A phase of θ degrees is n = θ ÷ 360.
  • Electrical length of a cable: n = L ÷ λc wavelengths, or 360° × L ÷ λc.
  • Delay: τ = L ÷ (VF × c). A time-domain reflectometer shows the time to a fault and back, so the distance is VF × c × t ÷ 2.
  • Phasing harness: a branch of an odd number of quarter waves turns the antenna impedance ZA into Z0² ÷ ZA; a branch of whole half waves repeats ZA. N equal branches in parallel give that impedance ÷ N.

Worked examples

  • A quarter wave of coax with VF 0.66 at 145 MHz: λc = 0.66 × 299,792,458 ÷ 145,000,000 = 1.3646 m, so the cable is 0.34114 m long (13.43 in).
  • 10 m of that cable at 145 MHz is 7.3283 wavelengths (2,638.19°) long and delays the signal by 50.540 ns.
  • A TDR shows a reflection after 100 ns on cable with VF 0.66: the fault is 9.8932 m away.
  • Two 50 Ω antennas fed by branches of 75 Ω coax, each 5 quarter waves (1.7057 m at 145 MHz with VF 0.66): each branch shows 75² ÷ 50 = 112.5 Ω, and the two in parallel give 56.25 Ω, a VSWR of 1.125 on a 50 Ω feed line.