Works on this device
RF Cable Length Calculator
Find the length of coax or another line for a quarter wave, a half wave or any phase at a frequency, using the velocity factor of the cable. You can also find the electrical length and delay of a cable you have, a length or a fault from a TDR time, and the branch lengths of a phasing harness.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out, for example Cable length for a phase or a fraction of a wavelength.
- Type the frequency and the velocity factor of your cable from its data sheet.
- Type the fraction of a wavelength (such as 1/4) or the phase in degrees. To make the cable long enough to reach, type the shortest length you need.
- Choose Calculate. Cut the cable a little long and trim it while you measure, because the velocity factor varies between batches.
The formulas
- Wavelength in the cable: λc = VF × c ÷ f, with c = 299,792,458 m/s and VF the velocity factor.
- Physical length for a fraction n of a wavelength: L = n × λc. A phase of θ degrees is n = θ ÷ 360.
- Electrical length of a cable: n = L ÷ λc wavelengths, or 360° × L ÷ λc.
- Delay: τ = L ÷ (VF × c). A time-domain reflectometer shows the time to a fault and back, so the distance is VF × c × t ÷ 2.
- Phasing harness: a branch of an odd number of quarter waves turns the antenna impedance ZA into Z0² ÷ ZA; a branch of whole half waves repeats ZA. N equal branches in parallel give that impedance ÷ N.
Worked examples
- A quarter wave of coax with VF 0.66 at 145 MHz: λc = 0.66 × 299,792,458 ÷ 145,000,000 = 1.3646 m, so the cable is 0.34114 m long (13.43 in).
- 10 m of that cable at 145 MHz is 7.3283 wavelengths (2,638.19°) long and delays the signal by 50.540 ns.
- A TDR shows a reflection after 100 ns on cable with VF 0.66: the fault is 9.8932 m away.
- Two 50 Ω antennas fed by branches of 75 Ω coax, each 5 quarter waves (1.7057 m at 145 MHz with VF 0.66): each branch shows 75² ÷ 50 = 112.5 Ω, and the two in parallel give 56.25 Ω, a VSWR of 1.125 on a 50 Ω feed line.
Limits you should know
- The velocity factor is your value from the data sheet. It differs by a few per cent between makers and batches, and the error grows with the length, so trim long phasing lines by measurement.
- The lengths do not count connectors or adapters, and the phase holds at the design frequency only.
- The harness rules take matched antennas that do not couple to each other and a lossless line. For the impedance step itself, see the Impedance Transformer Calculator; for a stub match, the Impedance Matching Calculator; for the loss of the cable, the Coax Cable Loss Calculator; for antenna lengths, the RF Wavelength & Antenna Length Calculator.
- Power cables are sized by current and voltage drop: see the Voltage Drop Calculator and the Wire Resistance Calculator.