Works on this device
Impedance Transformer Calculator
Match two real impedances with lengths of transmission line. Find the impedance and length of a quarter-wave transformer and its bandwidth for a VSWR limit, or design a binomial or Chebyshev transformer of several sections for a wider band.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Quarter-wave transformer for one section, or Multi-section transformer for a wider band.
- Type the source or line impedance and the load resistance, such as 50 Ω and 100 Ω, and the design frequency.
- Type the velocity factor of the line, so that the length is right for your cable or board.
- Type the largest VSWR (or the smallest return loss) you accept. Choose Calculate to see the impedances, lengths, bandwidth and the reflection across the band.
The formulas
- Quarter-wave transformer: Z1 = √(Zs × RL), a quarter wavelength long at the design frequency: length = VF × c ÷ (4 f0).
- Bandwidth of one section for a reflection limit Γm: Δf ÷ f0 = 2 − (4 ÷ π) × arccos[Γm ÷ √(1 − Γm²) × 2√(Zs RL) ÷ |RL − Zs|].
- Binomial: the steps reflect Γn = A × C(N, n), with A = 2^−(N+1) × ln(RL ÷ Zs). Bandwidth: Δf ÷ f0 = 2 − (4 ÷ π) × arccos[½ × (Γm ÷ |A|)^(1/N)].
- Chebyshev: sec θm = cosh[(1/N) × arcosh(|ln(RL ÷ Zs)| ÷ (2 Γm))]. The Γn are the coefficients of Γm × T_N(sec θm × cos θ) written as a sum of cos(kθ). Bandwidth: Δf ÷ f0 = 2 − 4 θm ÷ π.
- Section impedances: ln(Zn+1 ÷ Zn) = 2 Γn, starting from Zs. This rule of small reflections ends exactly on RL.
- The reflection of the sections that come out is then worked out exactly with the line equation, so you can see how close the design formulas come.
- The relations are those in D. M. Pozar, Microwave Engineering, chapter on impedance matching and tuning.
Worked examples
- A 100 Ω load on a 50 Ω line at 1,000 MHz: Z1 = √(50 × 100) = 70.711 Ω. In air the line is 74.948 mm long; in coax with a velocity factor of 0.66 it is 49.466 mm. For a VSWR of at most 1.2 the band is 33.25% wide, from 833.74 to 1,166.26 MHz.
- A piece of 75 Ω line a quarter wave long matches 50 Ω to a load of 75² ÷ 50 = 112.5 Ω.
- Binomial, three sections, 50 Ω to 100 Ω: 54.525, 70.711 and 91.700 Ω. For a VSWR of 1.2 the band is 88.45% wide.
- Chebyshev, three sections, the same ends and limit: 59.311, 70.711 and 84.301 Ω, and the band is 120.31% wide.
Limits you should know
- Both ends must be real (resistive). For a load with reactance, use the Impedance Matching Calculator with an L-network or a stub.
- The lines are lossless TEM lines. Steps between sections, connectors and dispersion are not counted. For the width of a board trace of each impedance, use the Microstrip Calculator; for cable lengths the RF Cable Length Calculator.
- The multi-section designs use approximations of small reflections, so the exact reflection can go a little above the limit. The result shows the exact value at the band edges.
- Wound transformers (baluns, ununs, Guanella and Ruthroff types) are not designed here. The turns ratio of a transformer for an impedance ratio and the per-cent impedance of a power transformer are in the Transformer Calculator. For VSWR and return loss, see the VSWR & Return Loss Calculator.