Find the two parts of an L-network that match a load, such as an antenna or an amplifier input, to 50 Ω or another impedance at one frequency. You also get the node Q, the nearest standard part values and the VSWR they give, or the place and length of a matching stub on a line.

Enter your values

Use this to match a load, such as an antenna or an amplifier input, to 50 Ω with one inductor and one capacitor.

Your values

The real impedance you match to, such as a 50 Ω line or the output of a stage.

The real part of the load impedance, such as an antenna feed point.

The imaginary part. Positive for an inductive load, negative (type a minus sign) for a capacitive one. Type 0 for a pure resistance.

Inductors and capacitors are often sold in E12 or E24 values. Check what your supplier has.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose L-network for an inductor and a capacitor, or Single-stub match for a piece of line.
  2. Type the impedance you match to (Z0), usually 50 Ω, and the load as a resistance RL and a reactance XL. A capacitive load has a negative reactance.
  3. Type the frequency. For the L-network, choose the series of standard values your parts come in, such as E12.
  4. Choose Calculate. The table lists every solution with its parts, node Q and the VSWR with standard values.

The formulas

  • L-network, part across the load first (works when RL² + XL² ≥ Z0 × RL): B = [XL ± √(RL ÷ Z0) × √(RL² + XL² − Z0 RL)] ÷ (RL² + XL²), then X = 1 ÷ B + XL Z0 ÷ RL − Z0 ÷ (B RL).
  • L-network, part in series with the load first (works when RL < Z0): X = ±√(RL (Z0 − RL)) − XL and B = ±√((Z0 − RL) ÷ RL) ÷ Z0.
  • Parts: a positive reactance X is an inductor L = X ÷ (2πf); a negative X is a capacitor C = −1 ÷ (2πf X). A positive susceptance B is a capacitor C = B ÷ (2πf); a negative B is an inductor L = −1 ÷ (2πf B).
  • Node Q = reactance ÷ resistance at the point between the two parts. For two resistances it is √(R high ÷ R low − 1).
  • Single stub (shunt): with t = tan(βd), t = [XL ± √(RL((Z0 − RL)² + XL²) ÷ Z0)] ÷ (RL − Z0), and d ÷ λ = arctan(t) ÷ 2π (plus ½ when t is negative). The stub cancels the susceptance B at that point. A series stub uses the same relations with admittances.
  • The relations are those in D. M. Pozar, Microwave Engineering, chapter on impedance matching and tuning.

Worked examples

  • A load of 200 − j100 Ω on a 100 Ω line at 500 MHz: a 0.92277 pF capacitor across the load and a 38.985 nH inductor in series, or a 46.139 nH inductor across the load and a 2.599 pF capacitor in series. The node Q is 1.2247.
  • A load of 20 − j30 Ω matched to 50 Ω at 100 MHz has four solutions. One is an 86.731 nH inductor in series with the load and a 38.985 pF capacitor across the line; with the nearest E12 values (82 nH and 39 pF) the VSWR is 1.16.
  • A load of 60 − j80 Ω on a 50 Ω line at 2 GHz with a short-circuited shunt stub: the stub goes 0.1104 λ from the load and is 0.0950 λ long, or 0.2594 λ from the load and 0.4050 λ long.

Limits you should know

  • The match is exact at one frequency only. The network is lossless, and the source is a real impedance.
  • Real inductors and capacitors have tolerances, losses and stray inductance and capacitance. At high frequencies the board layout changes the values, so check on the bench or in a simulator.
  • Pi and T networks, broadband matching, and drawing the match on a Smith chart are not done here. For a match between two real impedances over a wider band, use the Impedance Transformer Calculator; for the chart, the Smith Chart Tool.
  • A resistive matching pad is in the RF Attenuator Calculator, a transformer turns ratio for two impedances in the Transformer Calculator, the impedance of an antenna in the Antenna Impedance Calculator and the VSWR of a mismatch in the VSWR & Return Loss Calculator.

Related tools