Works on this device
Impedance Matching Calculator
Find the two parts of an L-network that match a load, such as an antenna or an amplifier input, to 50 Ω or another impedance at one frequency. You also get the node Q, the nearest standard part values and the VSWR they give, or the place and length of a matching stub on a line.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose L-network for an inductor and a capacitor, or Single-stub match for a piece of line.
- Type the impedance you match to (Z0), usually 50 Ω, and the load as a resistance RL and a reactance XL. A capacitive load has a negative reactance.
- Type the frequency. For the L-network, choose the series of standard values your parts come in, such as E12.
- Choose Calculate. The table lists every solution with its parts, node Q and the VSWR with standard values.
The formulas
- L-network, part across the load first (works when RL² + XL² ≥ Z0 × RL): B = [XL ± √(RL ÷ Z0) × √(RL² + XL² − Z0 RL)] ÷ (RL² + XL²), then X = 1 ÷ B + XL Z0 ÷ RL − Z0 ÷ (B RL).
- L-network, part in series with the load first (works when RL < Z0): X = ±√(RL (Z0 − RL)) − XL and B = ±√((Z0 − RL) ÷ RL) ÷ Z0.
- Parts: a positive reactance X is an inductor L = X ÷ (2πf); a negative X is a capacitor C = −1 ÷ (2πf X). A positive susceptance B is a capacitor C = B ÷ (2πf); a negative B is an inductor L = −1 ÷ (2πf B).
- Node Q = reactance ÷ resistance at the point between the two parts. For two resistances it is √(R high ÷ R low − 1).
- Single stub (shunt): with t = tan(βd), t = [XL ± √(RL((Z0 − RL)² + XL²) ÷ Z0)] ÷ (RL − Z0), and d ÷ λ = arctan(t) ÷ 2π (plus ½ when t is negative). The stub cancels the susceptance B at that point. A series stub uses the same relations with admittances.
- The relations are those in D. M. Pozar, Microwave Engineering, chapter on impedance matching and tuning.
Worked examples
- A load of 200 − j100 Ω on a 100 Ω line at 500 MHz: a 0.92277 pF capacitor across the load and a 38.985 nH inductor in series, or a 46.139 nH inductor across the load and a 2.599 pF capacitor in series. The node Q is 1.2247.
- A load of 20 − j30 Ω matched to 50 Ω at 100 MHz has four solutions. One is an 86.731 nH inductor in series with the load and a 38.985 pF capacitor across the line; with the nearest E12 values (82 nH and 39 pF) the VSWR is 1.16.
- A load of 60 − j80 Ω on a 50 Ω line at 2 GHz with a short-circuited shunt stub: the stub goes 0.1104 λ from the load and is 0.0950 λ long, or 0.2594 λ from the load and 0.4050 λ long.
Limits you should know
- The match is exact at one frequency only. The network is lossless, and the source is a real impedance.
- Real inductors and capacitors have tolerances, losses and stray inductance and capacitance. At high frequencies the board layout changes the values, so check on the bench or in a simulator.
- Pi and T networks, broadband matching, and drawing the match on a Smith chart are not done here. For a match between two real impedances over a wider band, use the Impedance Transformer Calculator; for the chart, the Smith Chart Tool.
- A resistive matching pad is in the RF Attenuator Calculator, a transformer turns ratio for two impedances in the Transformer Calculator, the impedance of an antenna in the Antenna Impedance Calculator and the VSWR of a mismatch in the VSWR & Return Loss Calculator.