Toolvito

Calculates on this device. File exports run online.

Smith Chart Tool

Type an impedance, an admittance, a reflection coefficient or S11 and see it on a Smith chart with its VSWR, return loss and equivalent parts. Move it along a transmission line, match it with an L network of inductors and capacitors, a single stub or a quarter-wave transformer, or open a Touchstone file to plot a whole frequency sweep. Every chart can be saved as an SVG picture, and the box below finds the best standard-value matching network for a whole band.

Enter your values

Γ, VSWR, return loss and the equivalent parts of an impedance, an admittance, Γ or S11.

Your values

The impedance of the line or the system, often 50 Ω or 75 Ω.

Positive for an inductive load, negative for a capacitive one.

For the parts (inductance or capacitance) and for lengths in millimetres.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose the button below them.

Best standard-value network for a band

Best standard-value network for a band

The load of the result above is used: all frequencies of Plot a frequency sweep (within its band), or the one frequency of Match a load. Every L network, and if you like every Pi and T network, of inductors and capacitors from the series you choose is tried, and the best of each shape and choice of parts is listed by its worst VSWR over the band.

More options

The chart and the matching above work in your browser; files you open are read there. When you use this box, Z0 and the load at each frequency (up to 401 of them) are sent to the Toolvito server to search the networks. Download the result within one hour after the job finishes. Choose Delete files now to request earlier removal. The hourly cleanup normally removes files within one to two hours after completion.

How to use it

  1. Choose Plot a load, set Z0 (often 50 Ω) and type the load. Press Plot the load: the chart shows the point and its VSWR circle.
  2. Choose Move along a line to see the input impedance through a length of line, or Match a load for L networks, stubs and quarter-wave transformers at one frequency.
  3. Choose Plot a frequency sweep and paste or open a Touchstone file (.s1p, or .s2p for S11) from a network analyser or a simulator, or a table of frequency, R and X.
  4. Use Save the Smith chart (SVG) to keep the picture; it opens in any browser and in drawing programs.

Reading the chart

  • The centre is a perfect match (z = 1, Γ = 0); the outer circle is total reflection. The right end is an open circuit, the left end a short.
  • Solid circles are constant resistance and arcs constant reactance: the upper half is inductive, the lower half capacitive. The dashed grid, when shown, is the admittance chart.
  • Moving toward the source along a line turns the point clockwise around the centre: half a wavelength is one full turn.
  • A series part moves the point along its resistance circle; a part across the line moves it along its conductance circle.

Uses of the Smith chart

Engineers use it to see how far an antenna, an amplifier input or a cable end is from a match, to design matching networks and stubs, and to read network analyser sweeps. Simulators such as LTspice or ADS can export Touchstone files that this page reads.

Limits

Lines are uniform with a real characteristic impedance; parts are ideal (the server box can add an inductor Q). Real inductors and capacitors also have tolerances, self-resonance and pad parasitics, so check a design with the parts you buy.

Related tools