Works on this device
First Order Reaction Calculator
Work through a first order reaction: how much is left after a time, how long a change takes, k and the half-life from a measured change, and k from a table of measurements.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to find: the concentration after a time, k from a measured change, the time for a change, the half-life, or k from a table of measurements.
- Enter the numbers. Concentrations may be in any unit (mol/L, grams, a pressure), as long as they are all in the same one. Type the unit name to label the answers.
- Choose the time unit of k, or the unit of the times you type. k is given per that time unit.
- Choose Calculate. The result shows the answer, the half-life and the working.
The first order integrated rate law
- Rate law: rate = −d[A]/dt = k[A]. The rate is proportional to the concentration of A.
- Integrated law: ln[A] = ln[A]0 − k t, so [A] = [A]0 × e^(−k t).
- Rate constant: k = ln([A]0 ÷ [A]) ÷ t. With x% decomposed, [A]0 ÷ [A] = 100 ÷ (100 − x).
- Time: t = ln([A]0 ÷ [A]) ÷ k.
- Half-life: t½ = ln 2 ÷ k = 0.693147 ÷ k. It is the same at every concentration. The mean lifetime is 1/k.
- Plot: ln[A] against t is a straight line with slope −k. A curved line means the reaction is not first order.
- k has the unit of 1/time, such as s⁻¹ or min⁻¹.
Worked examples
A first order reaction takes 40 minutes for 30% decomposition. 70% is left, so k = ln(100 ÷ 70) ÷ 40 = 0.356675 ÷ 40 = 0.00891687 min⁻¹. The half-life is 0.693147 ÷ 0.00891687 = 77.7343 minutes.
Concentration after a time. [A]0 = 0.5 mol/L and k = 0.0089 min⁻¹. After 60 minutes, [A] = 0.5 × e^(−0.534) = 0.293128 mol/L.
Time for 99%. With k = 0.0089 min⁻¹, 99% has reacted after ln(100) ÷ 0.0089 = 517.435 minutes, about 6.64 half-lives.
Plot. Measurements at 0, 10, 20, 30, 40 and 50 minutes of 0.500, 0.393, 0.310, 0.243, 0.191 and 0.150 mol/L give k = 0.0240800 min⁻¹ with a standard error of 0.0000368, a half-life of 28.7852 minutes and r² = 0.99999.
Limits you should know
- The reaction must be first order in A at a constant temperature. Many reactions are first order only when another reactant is in large excess (pseudo-first order).
- k here belongs to the rate of loss of A, −d[A]/dt. If your book writes the rate of 2A → products as −½ d[A]/dt, double its k first.
- The plot mode fits ln[A] without weights. Points near the end, where [A] is small, carry more measurement error on the log scale.
- For other orders use the Second Order Reaction Calculator or the Reaction Half Life Calculator. For how k changes with temperature, use the Arrhenius Equation Calculator.