Toolvito

Works on this device

Second Order Reaction Calculator

Work through a second order reaction: how much is left after a time, how long a change takes, k from measurements, the half-life, and the case of two reactants A + B with different starting amounts.

Enter your values

For rate = k[A]²: how much A is left after a time.

Your values

Type 2.5e-3 for 2.5 × 10⁻³.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to find: the concentration after a time, k, the time for a change, the half-life, two reactants A + B, or k from a table of measurements.
  2. Enter the concentrations in M, mM, µM or nM. k is in M⁻¹ per time (L mol⁻¹ per time); choose its time unit.
  3. For two reactants, enter both starting concentrations. One A must react with one B.
  4. Choose Calculate. The result shows the answer, the half-life and the working.

The second order integrated rate laws

  • One reactant (rate = −d[A]/dt = k[A]²): 1/[A] = 1/[A]0 + k t. So [A] = [A]0 ÷ (1 + k [A]0 t), k = (1/[A] − 1/[A]0) ÷ t and t = (1/[A] − 1/[A]0) ÷ k.
  • Half-life: t½ = 1 ÷ (k [A]0). It depends on [A]0, and each later half-life is twice as long as the one before.
  • Two reactants (rate = k[A][B], [A]0 ≠ [B]0): ln([B][A]0 ÷ ([A][B]0)) = ([B]0 − [A]0) k t, where [A] = [A]0 − x and [B] = [B]0 − x after x mol/L has reacted. When [A]0 = [B]0 the law is the one-reactant law.
  • Plot: 1/[A] against t is a straight line with slope k and intercept 1/[A]0.
  • k has the unit M⁻¹ s⁻¹ = L mol⁻¹ s⁻¹ (or per minute, per hour).

Worked examples

Concentration after a time. [A]0 = 0.1 M and k = 0.5 M⁻¹ min⁻¹. After 30 minutes, 1/[A] = 10 + 0.5 × 30 = 25 M⁻¹, so [A] = 0.04 M. The first half-life is 1 ÷ (0.5 × 0.1) = 20 minutes, the next one 40 minutes.

Time. With the same k and [A]0, [A] falls to 0.025 M after (40 − 10) ÷ 0.5 = 60 minutes.

Two reactants. [A]0 = 0.1 M, [B]0 = 0.15 M and k = 0.5 M⁻¹ min⁻¹. After 30 minutes [A] = 0.0229832 M and [B] = 0.0729832 M: 77.0168% of A has reacted. [A] reaches 0.05 M after 11.5073 minutes.

Plot. Measurements at 0, 5, 10, 20, 30 and 40 minutes of 0.200, 0.154, 0.125, 0.0909, 0.0714 and 0.0588 M give k = 0.300259 M⁻¹ min⁻¹ with a standard error of 0.0000839, and [A]0 = 0.200134 M.

Limits you should know

  • The reaction must be second order at a constant temperature. Two concentrations cannot show the order: use the plot mode, which compares zero, first and second order lines.
  • k here belongs to the rate of loss of A, −d[A]/dt. If your book writes the rate of 2A → products as −½ d[A]/dt, double its k first.
  • The two-reactant law is for one A reacting with one B. Other ratios follow another law.
  • For first order use the First Order Reaction Calculator. For half-lives of all orders, use the Reaction Half Life Calculator.

Related tools