Toolvito

Works on this device

Rate Constant Calculator

Work out the rate constant k of a reaction from measured concentrations, from its half-life, or from an initial rate and the rate law. Every answer states the unit of k for the order.

Enter your values

For a reaction of zero, first or second order: k from [A]0, [A] and the time between them.

Your values

The time between the two concentrations. k is given per this time unit.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose how you want to find k: from concentrations at two times, from the half-life, from an initial rate and the rate law, or the units of k.
  2. Choose the order of the reaction (zero, first or second) when it is asked.
  3. Enter the concentrations in M, mM, µM or nM and the time in seconds, minutes, hours, days or years. k is given per the time unit you type.
  4. Choose Calculate. The result shows k, its unit, the half-life and the working.

The formulas

  • Zero order (rate = k): [A] = [A]0 − k t, so k = ([A]0 − [A]) ÷ t. Half-life t½ = [A]0 ÷ (2k), so k = [A]0 ÷ (2 t½).
  • First order (rate = k[A]): ln[A] = ln[A]0 − k t, so k = ln([A]0 ÷ [A]) ÷ t. Half-life t½ = ln 2 ÷ k, so k = 0.693147 ÷ t½.
  • Second order (rate = k[A]²): 1/[A] = 1/[A]0 + k t, so k = (1/[A] − 1/[A]0) ÷ t. Half-life t½ = 1 ÷ (k [A]0), so k = 1 ÷ (t½ [A]0).
  • Rate law: for rate = k[A]^m[B]^n, k = rate ÷ ([A]^m × [B]^n). The overall order is m + n.
  • Here k belongs to the rate of loss of A, −d[A]/dt. If your book defines the rate of 2A → products as −½ d[A]/dt, its k is half of this one.

Units of the rate constant

The unit of k depends on the overall order n: it is (concentration)^(1 − n) per time. With concentrations in mol/L (M) and time in seconds:

Unit of k for each overall order
Overall order Rate law example Unit of k Same unit written out
0 rate = k M s⁻¹ mol L⁻¹ s⁻¹
1 rate = k[A] s⁻¹ s⁻¹
2 rate = k[A]² or k[A][B] M⁻¹ s⁻¹ L mol⁻¹ s⁻¹
3 rate = k[A]²[B] M⁻² s⁻¹ L² mol⁻² s⁻¹
n rate = k[A]ⁿ M^(1 − n) s⁻¹ L^(n − 1) mol^(1 − n) s⁻¹

Worked examples

First order from concentrations. [A] falls from 0.1 M to 0.04 M in 30 minutes. k = ln(0.1 ÷ 0.04) ÷ 30 min = 0.916291 ÷ 30 = 0.0305430 min⁻¹ (5.09050 × 10⁻⁴ s⁻¹), and the half-life is 22.6941 minutes.

Second order, same numbers. k = (1/0.04 − 1/0.1) ÷ 30 = (25 − 10) ÷ 30 = 0.5 M⁻¹ min⁻¹.

From a half-life. A first order reaction has t½ = 25 minutes, so k = 0.693147 ÷ 25 = 0.0277259 min⁻¹.

From a rate law. rate = k[A][B]², with an initial rate of 2.4 × 10⁻⁴ M/s at [A] = 0.1 M and [B] = 0.2 M. k = 2.4 × 10⁻⁴ ÷ (0.1 × 0.2²) = 0.06 M⁻² s⁻¹, overall order 3.

Units. A gas reaction has k = 1 × 10⁻¹¹ cm³ molecule⁻¹ s⁻¹. In M⁻¹ s⁻¹ this is 1 × 10⁻¹¹ × 6.02214076 × 10²⁰ = 6.02214 × 10⁹ M⁻¹ s⁻¹.

Limits you should know

  • You must know the order of the reaction. Two concentrations cannot show the order; for many measurements use the plot in the First Order Reaction Calculator or the Second Order Reaction Calculator, which compare the orders.
  • The formulas assume a constant temperature and volume. To see how k changes with temperature, use the Arrhenius Equation Calculator.
  • Units in pressure (such as atm⁻¹ s⁻¹ for a gas) need the temperature and are not converted here.
  • A rate constant has no unit dimension of its own in this tool: it is a number with its unit written as text.

Related tools