Toolvito

Works on this device

Thermal Radiation Calculator

Warm surfaces send heat to cooler ones by thermal radiation, even through empty space. Enter the temperatures, emissivities and sizes of two surfaces to find the net heat that flows between them.

Enter your values

Surface 1 is the inner surface (a pipe, a ball, an object in a room); surface 2 surrounds it completely.

Your values

Surface 1 is the inner or the first surface. Absolute zero is 0 K, −273.15 °C or −459.67 °F.

From 0 to 1, from a table for the material, its finish and its temperature.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose the arrangement: one surface inside another (a body in a room, a pipe in a pipe, a sphere in a sphere), two large parallel plates, two surfaces with a view factor, or the radiation heat transfer coefficient.
  2. Enter the two temperatures. °C and °F are turned into kelvin, which radiation needs.
  3. Enter the emissivity of each surface (0 to 1) from a table for its material and finish, and the sizes.
  4. Choose Calculate. A result above zero is heat flowing from surface 1 to surface 2.

The formulas

All of them follow from the Stefan-Boltzmann law with σ = 5.670374 × 10^-8 W/(m²·K⁴) and grey surfaces.

  • Small body in a large room: Q = ε1 × σ × A1 × (T1⁴ − T2⁴).
  • Two large parallel plates: q = σ × (T1⁴ − T2⁴) ÷ (1 ÷ ε1 + 1 ÷ ε2 − 1) per square metre.
  • Concentric cylinders or spheres: Q = σ × A1 × (T1⁴ − T2⁴) ÷ (1 ÷ ε1 + (1 − ε2) ÷ ε2 × A1 ÷ A2), with A1 ÷ A2 = D1 ÷ D2 for cylinders and (D1 ÷ D2)² for spheres.
  • Two surfaces of an enclosure (radiation network): Q12 = σ(T1⁴ − T2⁴) ÷ ((1 − ε1) ÷ (A1 ε1) + 1 ÷ (A1 F12) + (1 − ε2) ÷ (A2 ε2)).
  • Radiation heat transfer coefficient: h_r = ε × σ × (T_s² + T_sur²) × (T_s + T_sur), so that q = h_r × (T_s − T_sur) and h_r can be added to a convection coefficient.

Worked examples

An object of 0.5 m² at 300 °C (ε = 0.8) in a room whose walls are at 50 °C: Q = 0.8 × 5.670374 × 10^-8 × 0.5 × (573.15⁴ − 323.15⁴) = 2,200.3 W.

Two large plates at 300 °C and 50 °C with emissivities 0.8 and 0.6: q = 5.670374 × 10^-8 × (573.15⁴ − 323.15⁴) ÷ (1 ÷ 0.8 + 1 ÷ 0.6 − 1) = 2,869.9 W/m². Black plates would exchange 5,500.7 W/m².

A pipe of 50 mm at 300 °C (ε = 0.8) inside a pipe of 100 mm at 50 °C (ε = 0.6), 1 m long: A1 = 0.15708 m², A1 ÷ A2 = 0.5, and Q = 545.7 W.

A surface at 60 °C (ε = 0.9) in a room at 20 °C: h_r = 0.9 × 5.670374 × 10^-8 × (333.15² + 293.15²) × (333.15 + 293.15) = 6.294 W/(m²·K), and q = 6.294 × 40 = 251.8 W/m².

Limits you should know

  • The surfaces are grey and diffuse: one emissivity for all wavelengths and directions. Real emissivities change with the wavelength and the temperature; use a value for your conditions.
  • The gas between the surfaces is taken as transparent. Water vapour and CO2 in hot combustion gases do take in radiation, and that is not covered here.
  • Conduction and convection are not counted, except as a convection coefficient that you type in the h_r option.
  • For the power of one body on its own, use the Stefan Boltzmann Calculator; for the spectrum, the Blackbody Radiation Calculator; for conduction and convection, the Heat Transfer Calculator.

Related tools