Works on this device
Heat Transfer Calculator
Heat moves in three ways: conduction through solids, convection by a moving fluid, and radiation as infrared light. Choose one, enter what you know, and get the heat flow with the working. Two more choices cover a fin on a hot wall and a small body that cools or warms over time.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the kind of heat transfer: conduction, convection, radiation, a fin, or a body that cools over time.
- For convection, choose what you want to find: the heat flow, the coefficient h, the area or the surface temperature.
- Enter the values with their units. Temperatures can be in °C, °F or K.
- Choose Calculate. The result shows the heat flow, the heat flux and the working.
The three ways heat moves
- Conduction (Fourier's law): Q = k × A × (T1 − T2) ÷ L. Heat passes through a solid from the warm side to the cool side. For pipes, balls and layers, see the Conduction Calculator.
- Convection (Newton's law of cooling): Q = h × A × (Ts − T∞). A moving fluid carries heat to or from a surface. The coefficient h depends on the flow; the Convection Calculator works it out from the flow.
- Radiation (Stefan-Boltzmann law): Q = ε × σ × A × (Ts⁴ − Tsur⁴), with temperatures in kelvin and σ = 5.670374 × 10⁻⁸ W/(m²·K⁴). See the Stefan Boltzmann Calculator and the Thermal Radiation Calculator for more cases.
- Fin: m = √(h P ÷ (k A_c)); for an insulated tip q = √(h P k A_c) × (Tb − T∞) × tanh(mL).
- Lumped body: T − T∞ = (Ti − T∞) × e^(−t ÷ τ), with τ = ρ × c × V ÷ (h × A). Good when the Biot number h × (V ÷ A) ÷ k is below 0.1.
Worked examples
Conduction: a brick wall 220 mm thick (k = 0.72 W/(m·K)) with an area of 2 m², at 20 °C on one face and 5 °C on the other. R = 0.22 ÷ (0.72 × 2) = 0.152778 K/W, so Q = 15 ÷ 0.152778 = 98.1818 W.
Convection: a surface of 2 m² at 80 °C in air at 20 °C with h = 25 W/(m²·K) gives Q = 25 × 2 × 60 = 3000 W.
Radiation: the same surface with ε = 0.9 and surroundings at 20 °C radiates a net 0.9 × 5.670374 × 10⁻⁸ × 2 × (353.15⁴ − 293.15⁴) = 833.748 W, and h_r = 6.9479 W/(m²·K).
Fin: an aluminium pin (k = 237 W/(m·K)) 5 mm across and 50 mm long, with h = 25 W/(m²·K), base at 100 °C and air at 25 °C, loses 1.40699 W from its sides and tip; its efficiency is 93.21%.
Limits you should know
- Steady state for conduction, convection, radiation and the fin; the lumped body changes with time but has one temperature inside.
- The coefficient h and the emissivity are your own figures. They change with the flow, the surface and the temperature.
- The radiation choice is for a small surface in large surroundings. Two surfaces that see each other need view factors.
- To heat or cool a mass of a material (Q = m × c × ΔT), use the Specific Heat Calculator. For the heat flow per square metre in more cases, see the Heat Flux Calculator; for several layers and the U-value, the Thermal Resistance Calculator.
- This is arithmetic for learning and checking, not a design approval.