Toolvito

Works on this device

Heat Transfer Calculator

Heat moves in three ways: conduction through solids, convection by a moving fluid, and radiation as infrared light. Choose one, enter what you know, and get the heat flow with the working. Two more choices cover a fin on a hot wall and a small body that cools or warms over time.

Enter your values

Heat moving through a solid: Q = k × A × (T1 − T2) ÷ L.

Your values

0.72 W/(m·K) is an example for common brick. Use the value for your material, or fill in an example from the menu above.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose the kind of heat transfer: conduction, convection, radiation, a fin, or a body that cools over time.
  2. For convection, choose what you want to find: the heat flow, the coefficient h, the area or the surface temperature.
  3. Enter the values with their units. Temperatures can be in °C, °F or K.
  4. Choose Calculate. The result shows the heat flow, the heat flux and the working.

The three ways heat moves

  • Conduction (Fourier's law): Q = k × A × (T1 − T2) ÷ L. Heat passes through a solid from the warm side to the cool side. For pipes, balls and layers, see the Conduction Calculator.
  • Convection (Newton's law of cooling): Q = h × A × (Ts − T∞). A moving fluid carries heat to or from a surface. The coefficient h depends on the flow; the Convection Calculator works it out from the flow.
  • Radiation (Stefan-Boltzmann law): Q = ε × σ × A × (Ts⁴ − Tsur⁴), with temperatures in kelvin and σ = 5.670374 × 10⁻⁸ W/(m²·K⁴). See the Stefan Boltzmann Calculator and the Thermal Radiation Calculator for more cases.
  • Fin: m = √(h P ÷ (k A_c)); for an insulated tip q = √(h P k A_c) × (Tb − T∞) × tanh(mL).
  • Lumped body: T − T∞ = (Ti − T∞) × e^(−t ÷ τ), with τ = ρ × c × V ÷ (h × A). Good when the Biot number h × (V ÷ A) ÷ k is below 0.1.

Worked examples

Conduction: a brick wall 220 mm thick (k = 0.72 W/(m·K)) with an area of 2 m², at 20 °C on one face and 5 °C on the other. R = 0.22 ÷ (0.72 × 2) = 0.152778 K/W, so Q = 15 ÷ 0.152778 = 98.1818 W.

Convection: a surface of 2 m² at 80 °C in air at 20 °C with h = 25 W/(m²·K) gives Q = 25 × 2 × 60 = 3000 W.

Radiation: the same surface with ε = 0.9 and surroundings at 20 °C radiates a net 0.9 × 5.670374 × 10⁻⁸ × 2 × (353.15⁴ − 293.15⁴) = 833.748 W, and h_r = 6.9479 W/(m²·K).

Fin: an aluminium pin (k = 237 W/(m·K)) 5 mm across and 50 mm long, with h = 25 W/(m²·K), base at 100 °C and air at 25 °C, loses 1.40699 W from its sides and tip; its efficiency is 93.21%.

Limits you should know

  • Steady state for conduction, convection, radiation and the fin; the lumped body changes with time but has one temperature inside.
  • The coefficient h and the emissivity are your own figures. They change with the flow, the surface and the temperature.
  • The radiation choice is for a small surface in large surroundings. Two surfaces that see each other need view factors.
  • To heat or cool a mass of a material (Q = m × c × ΔT), use the Specific Heat Calculator. For the heat flow per square metre in more cases, see the Heat Flux Calculator; for several layers and the U-value, the Thermal Resistance Calculator.
  • This is arithmetic for learning and checking, not a design approval.