Work out heat transfer by convection. Solve Newton's law of cooling for any one value, or find the heat transfer coefficient h from the flow: along a flat plate, inside a pipe, or in still fluid (natural convection). The tool shows the Reynolds, Prandtl, Grashof, Rayleigh and Nusselt numbers and the working.

Enter your values

Heat carried between a surface and a moving fluid. Solve for the heat flow, h, the area or a temperature.

Your values

Your figure, or one worked out with the other choices of this tool.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want: Newton's law of cooling, flow along a plate, flow in a pipe, natural convection, or a Nusselt number or j factor you already have.
  2. For the flow choices, enter the fluid properties: density, viscosity, conductivity and specific heat. The menu fills in example values for air or water at 300 K; use values at your own temperature.
  3. Enter the speed or flow, the size and the two temperatures. For a pipe, choose the correlation that fits your Reynolds number.
  4. Choose Calculate. The result shows h, the dimensionless numbers, the heat flow and the working. A correlation used outside its range is refused with the reason.

The formulas

  • Newton's law of cooling: Q = h × A × (Ts − T∞). The heat flux is q = h × (Ts − T∞).
  • Numbers: Re = ρ V L ÷ μ, Pr = cp μ ÷ k, Gr = g β ΔT L³ ÷ ν², Ra = Gr × Pr, Nu = h L ÷ k, so h = Nu × k ÷ L.
  • Flat plate: laminar Nu = 0.664 Re^½ Pr^⅓ (Re up to 500,000); laminar then turbulent Nu = (0.037 Re^0.8 − 871) Pr^⅓ (Re up to 10⁸, Pr 0.6 to 60).
  • Pipe: Dittus-Boelter Nu = 0.023 Re^0.8 Pr^n (n = 0.4 heating, 0.3 cooling; Re from 10,000); Gnielinski Nu = (f/8)(Re − 1000) Pr ÷ (1 + 12.7 (f/8)^½ (Pr^⅔ − 1)) with f = (0.790 ln Re − 1.64)^−2 (Re 3,000 to 5,000,000); laminar Nu = 4.36 or 3.66.
  • Natural convection (Churchill and Chu): vertical plate Nu = {0.825 + 0.387 Ra^⅙ ÷ [1 + (0.492 ÷ Pr)^(9/16)]^(8/27)}²; horizontal cylinder the same form with 0.60 and 0.559.

Worked examples

Newton's law: a surface of 2 m² at 80 °C in a fluid at 20 °C with h = 25 W/(m²·K) passes Q = 25 × 2 × 60 = 3,000 W, a flux of 1,500 W/m².

Air at 300 K (ρ = 1.1614 kg/m³, μ = 0.01846 mPa·s, k = 0.0263 W/(m·K), cp = 1.007 kJ/(kg·K)) flows at 10 m/s along a plate 0.5 m long: Re = 314,572 and Pr = 0.706814, so the flow is laminar, Nu = 0.664 × Re^½ × Pr^⅓ = 331.739 and h = 331.739 × 0.0263 ÷ 0.5 = 17.4495 W/(m²·K).

Water at 300 K (ρ = 997 kg/m³, μ = 0.855 mPa·s, k = 0.613 W/(m·K), cp = 4.179 kJ/(kg·K)) at 1 m/s in a pipe of 50 mm: Re = 58,304.1 and Pr = 5.82878. Gnielinski gives f = 0.0202401, Nu = 347.738 and h = 4,263.27 W/(m²·K).

A vertical plate 0.5 m high at 80 °C in still air at 20 °C, with the air values above and β = 1 ÷ 323.15 K: Ra = 6.36771 × 10⁸, Nu = 106.863 and h = 5.62099 W/(m²·K).

Limits you should know

  • Each correlation is used only inside its range of Re and Pr, and the tool says when you are outside it. Correlations agree with tests to within about 10 to 25%.
  • Fluid properties are your figures; take them at the film temperature (plate, cylinder) or the mean fluid temperature (pipe). No property tables are built in.
  • Steady flow, smooth surfaces, one surface temperature. Entry lengths, rough pipes, fins, tube banks and boiling or condensing are not covered.
  • Radiation is not included. For convection and radiation from a surface together, see the Heat Flux Calculator; for conduction and radiation beside convection, the Heat Transfer Calculator; for a film as one part of a wall, the Thermal Resistance Calculator.
  • For the Reynolds number on its own, see the Reynolds Number Calculator. A convection oven in a kitchen is a different thing: its temperature conversion is in the Cooking Time & Schedule Calculator.
  • This is arithmetic for learning and checking, not a design approval.