Toolvito

Works on this device

Concrete Strength Estimator

Estimate the compressive strength of concrete: how it grows with age, the strength of your test cubes or cylinders from their failure loads, and the strength in place from its maturity with your own calibration.

Enter your values

The compressive strength at an age from the 28-day strength, or the reverse, by the relation of ACI 209R-92.

Your values

The 28-day strength of your concrete, from its specification or tests.

Type I is ordinary portland cement and Type III high-early-strength cement (ASTM C150). For other cements, type a and b fitted to your tests.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this estimator

  1. Choose Strength with age to go from the 28-day strength to another age, or from an early test to the 28-day strength.
  2. Pick the cement and curing of ACI 209R-92, or type your own constants a and b. Type the strength; the box starts empty, and Try an example fills in an example.
  3. Choose Strength of test cubes or cylinders and type the size and the failure loads of your specimens.
  4. Choose Strength from maturity to use a strength–maturity relation from your own laboratory tests.

The methods

  • ACI 209R-92, equation (2-1): f′c(t) = t ÷ (a + b t) × f′c28, with the age t in days. Table 2.2.1 gives a = 4.0 and b = 0.85 for moist-cured concrete with Type I cement, 2.3 and 0.92 with Type III, and 1.0 and 0.95 (Type I) or 0.70 and 0.98 (Type III) for steam curing.
  • Test specimens: strength = maximum load ÷ loaded area, side² for a cube and π d² ÷ 4 for a cylinder. The page gives the mean, the sample standard deviation and the coefficient of variation.
  • Maturity (ASTM C1074): S = a + b log10(M), with M the temperature–time factor in °C·h and a, b from your own calibration.

Worked examples

Concrete of 30 MPa at 28 days, moist cured with Type I cement, at 7 days: 7 ÷ (4.0 + 0.85 × 7) = 0.704, so about 21.1 MPa. The other way round, 20 MPa at 7 days points to about 20 ÷ 0.704 = 28.4 MPa at 28 days.

Three 150 mm cubes fail at 675, 690 and 702 kN. Each has 22,500 mm², so the strengths are 30.0, 30.7 and 31.2 MPa: a mean of 30.6 MPa with a standard deviation of 0.60 MPa.

With an example relation S = −65 + 25 log10(M) in MPa, concrete with a maturity of 3,000 °C·h has about −65 + 25 × 3.477 = 21.9 MPa. That relation is for trying the tool, not for your mix.

Limits you should know

  • Strength with age is an average relation. Real strength gain depends on the cement, additions, temperature and curing.
  • Cube and cylinder strengths of the same concrete differ, and the page does not convert between them. Acceptance rules for test results come from your code or specification.
  • A strength–maturity relation holds only for the mix it was made with. Find the maturity with the Concrete Curing Maturity Calculator.
  • The strength of a floor or a beam (its load capacity) is a structural design question and is not worked out here. For the water–cement ratio, see the Concrete Water Cement Ratio Calculator.
  • It is not professional advice.