Compressed Air Leak Cost Calculator
Find how much compressed air your leaks let out and what that air costs in a year. You type the discharge coefficient, the specific power of your compressor and your price: none is built in. The costs are estimates from the figures you type.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you know: the size of the holes, a leak flow, or the times of a load and unload test.
- For hole sizes, add one row for each size of leak. Type the diameter of the hole and how many such leaks there are.
- Type the pressure in the line that the gauge shows, and a discharge coefficient for the holes. The menu of examples can fill in a coefficient.
- Type the specific power of your compressor, the hours in a year that the system is under pressure, and your price for one kWh.
- Type the cost of the repair if you want the payback time.
- Choose Calculate. Try an example fills the empty boxes with example values, so that you can see how an option works.
What each option does
- Cost of leaks from the size of the holes: the flow through each hole by the nozzle equation for air, then the power, the energy and the cost, with a table for each size of leak.
- Cost of a leak flow that you know: the same cost for a flow from a survey, a flow meter or a test.
- Leak share from a load and unload test: the share of the compressor output that goes to leaks, from two times that you measure with every user of air shut off.
The formulas
- Choked flow. When the pressure around the pipe is below 52.8% of the absolute pressure in the line (for air, k = 1.4), the air leaves the hole at the speed of sound. Then mass flow = C × A × p × √(k ÷ (R × T)) × (2 ÷ (k + 1))^((k + 1) ÷ (2 × (k − 1))).
- C is the discharge coefficient, A the area of the hole, p the absolute pressure in the line, T the absolute temperature of the air in the line, and R the gas constant of dry air, 287.05 J/(kg·K).
- For air with k = 1.4 this is mass flow = 0.6847 × C × A × p ÷ √(R × T).
- Flow that is not choked (a gauge pressure below about 0.9 bar at sea level): mass flow = C × A × p × √(2 × k ÷ ((k − 1) × R × T) × (r^(2 ÷ k) − r^((k + 1) ÷ k))), with r = pressure around ÷ p.
- Free air flow = mass flow × R × T ÷ pressure around.
- Power = free air flow × specific power. Energy = power × hours under pressure. Cost = energy × price for one kWh.
- Leak share from a test = time loaded ÷ (time loaded + time unloaded).
- Simple payback time = cost of the repair ÷ cost of the leaks each year.
Worked examples
Hole sizes. A line at 7 bar gauge has one open drain valve that leaks like a hole of 3 mm, and four couplings that each leak like a hole of 1 mm. With a discharge coefficient of 0.61 and air at 20 °C, the 3 mm hole lets out 24.384 m³/h of free air and each 1 mm hole 2.709 m³/h. Together that is 35.221 m³/h, or 0.587 m³/min.
With a specific power of 6.5 kW for each m³/min, the leaks need 3.816 kW. Over 6,000 hours that is 22,893.6 kWh. At 0.12 for one kWh, the leaks cost 2,747.24 a year. A repair for 300 pays back in 1.3 months.
A known flow. A leak flow of 30 m³/h is 0.5 m³/min. At 6.5 kW for each m³/min that is 3.25 kW, 19,500 kWh in 6,000 hours and 2,340.00 a year.
Load and unload test. With every user shut off, a compressor runs loaded for 45 seconds and unloaded for 135 seconds. The leak share is 45 ÷ 180 = 25%. If the compressor delivers 600 m³/h, the leaks take 150 m³/h.
Where to find your figures
- Hole size: an estimate from a leak survey. Many surveys with an ultrasonic detector give a flow for each leak: use the option for a known flow then.
- Discharge coefficient: it depends on the shape of the leak. The examples in the menu, 0.61 for a hole with sharp edges and 0.97 for a well-rounded opening, are figures often used for air leaks. With 1 you get the ideal flow, which is the most that is possible.
- Specific power: the data sheet of your compressor, or its input power divided by its free air delivery. The compressed air energy calculator works it out.
- Hours under pressure: the hours that the system is kept at pressure, not only the hours of production.
- Electricity price for one kWh: your bill or contract.
- The values that Try an example fills in are for trying the tool. They are not the data of any real system and not current prices.
Limits you should know
- A real leak is a crack, a thread or a worn seal, not a clean round hole. The result from a hole size shows the order of size of the loss, not a measurement.
- The model takes dry air as an ideal gas, a steady pressure, and no loss of heat on the way through the hole.
- Free air is counted at the pressure around the pipe and at the temperature of the air in the line.
- The specific power is taken to stay the same when the leaks are closed. A compressor that only runs unloaded for longer saves less: the saving is reached when it runs less or at a lower speed.
- In the load and unload test, air users that cannot be shut off count as leaks.
- Only the electricity is priced. Wear of the compressor, lost production from low pressure and a demand charge are not counted.
- The yearly cost is rounded once to 2 decimal places, and a half is rounded away from zero.
- The costs are estimates from the figures you type. For a decision on spending, measure the leaks and ask a qualified engineer.