Works on this device
Weir Flow Calculator
A weir measures the flow in a channel from the height of the water above its crest. Work out the flow from that head, the head for a flow, or a table of flow against head.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Flow over a weir from the head, Head over a weir for a flow, or Rating table.
- Choose the type of weir and enter its size: the crest length, the end contractions of a rectangular weir, or the angle of a V-notch.
- Enter the head: the height of the still water surface above the crest, measured upstream of the weir.
- Check the discharge coefficient Cd. The starting value for each type is a labelled textbook example; use the value of your standard or a calibration.
- Choose Calculate. The result also shows the coefficient C of the short handbook forms, such as Q = 3.33 L H^1.5 in feet.
The formulas
- Sharp-crested rectangular: Q = Cd × (2/3) × √(2g) × L_e × H^(3/2), with L_e = L − 0.1 × n × H for n end contractions (Francis).
- V-notch: Q = Cd × (8/15) × √(2g) × tan(θ ÷ 2) × H^(5/2).
- Cipolletti (sides 1 across to 4 up): Q = Cd × (2/3) × √(2g) × L × H^(3/2), with the full crest length.
- Trapezoidal, any side slope z: Q = Cd × √(2g) × ((2/3) × L × H^(3/2) + (8/15) × z × H^(5/2)).
- Broad-crested: Q = Cd × (2/3)^(3/2) × √g × b × H^(3/2), from the critical depth 2H ÷ 3 on the crest.
Worked examples
A suppressed rectangular weir 1 m long with 0.2 m of water over it, Cd = 0.62: Q = 0.62 × (2/3) × √(2 × 9.80665) × 1 × 0.2^1.5 = 0.1637 m³/s, or 163.7 L/s. That is the same as Q = 1.831 × L × H^1.5 in metres, or 3.316 × L × H^1.5 in feet.
Turned round, 150 L/s over the same weir stands 0.1887 m above the crest.
A 90° V-notch with 0.25 m of head and Cd = 0.58 passes 0.04281 m³/s (42.81 L/s).
A broad-crested weir 2 m wide with 0.4 m of head and Cd = 0.85 passes 0.7331 m³/s.
Limits you should know
- Cd depends on the weir, the head and how it is built. The starting values are textbook examples; a standard such as ISO 1438 or a calibration gives the right value for your weir.
- The velocity of the water coming toward the weir is not added. In a small approach channel the real flow is larger.
- The water must fall clear of a sharp-crested weir, with air under the falling sheet, and the weir must not be drowned by the water downstream.
- A circular weir, a flume (such as a Parshall flume) and flow through an opening are not worked out here. For flow through a hole or a nozzle, use the Orifice Flow Calculator.
- The results are arithmetic for the values you type. This is not professional advice.
Related pages
- Flow in a ditch or open channel by the Manning equation: Open Channel Flow Calculator.
- The Manning equation for pipes and channels: Manning Equation Calculator.
- Flow through a valve of known Cv or Kv: Valve Cv Calculator.