A weir measures the flow in a channel from the height of the water above its crest. Work out the flow from that head, the head for a flow, or a table of flow against head.

Enter your values

The flow of water over a weir from the height of the water above its crest.

Your values

The width of the crest across the channel (for a trapezoidal weir, the bottom width of the notch).

0.62 is a textbook example for a sharp-crested rectangular weir (the Francis formula Q = 3.33 L H^1.5 in feet is Cd = 0.623). Use the value of your standard or a calibration.

The height of the still water surface above the crest (or above the bottom of the notch), measured upstream where the surface has not yet started to drop.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Flow over a weir from the head, Head over a weir for a flow, or Rating table.
  2. Choose the type of weir and enter its size: the crest length, the end contractions of a rectangular weir, or the angle of a V-notch.
  3. Enter the head: the height of the still water surface above the crest, measured upstream of the weir.
  4. Check the discharge coefficient Cd. The starting value for each type is a labelled textbook example; use the value of your standard or a calibration.
  5. Choose Calculate. The result also shows the coefficient C of the short handbook forms, such as Q = 3.33 L H^1.5 in feet.

The formulas

  • Sharp-crested rectangular: Q = Cd × (2/3) × √(2g) × L_e × H^(3/2), with L_e = L − 0.1 × n × H for n end contractions (Francis).
  • V-notch: Q = Cd × (8/15) × √(2g) × tan(θ ÷ 2) × H^(5/2).
  • Cipolletti (sides 1 across to 4 up): Q = Cd × (2/3) × √(2g) × L × H^(3/2), with the full crest length.
  • Trapezoidal, any side slope z: Q = Cd × √(2g) × ((2/3) × L × H^(3/2) + (8/15) × z × H^(5/2)).
  • Broad-crested: Q = Cd × (2/3)^(3/2) × √g × b × H^(3/2), from the critical depth 2H ÷ 3 on the crest.

Worked examples

A suppressed rectangular weir 1 m long with 0.2 m of water over it, Cd = 0.62: Q = 0.62 × (2/3) × √(2 × 9.80665) × 1 × 0.2^1.5 = 0.1637 m³/s, or 163.7 L/s. That is the same as Q = 1.831 × L × H^1.5 in metres, or 3.316 × L × H^1.5 in feet.

Turned round, 150 L/s over the same weir stands 0.1887 m above the crest.

A 90° V-notch with 0.25 m of head and Cd = 0.58 passes 0.04281 m³/s (42.81 L/s).

A broad-crested weir 2 m wide with 0.4 m of head and Cd = 0.85 passes 0.7331 m³/s.

Limits you should know

  • Cd depends on the weir, the head and how it is built. The starting values are textbook examples; a standard such as ISO 1438 or a calibration gives the right value for your weir.
  • The velocity of the water coming toward the weir is not added. In a small approach channel the real flow is larger.
  • The water must fall clear of a sharp-crested weir, with air under the falling sheet, and the weir must not be drowned by the water downstream.
  • A circular weir, a flume (such as a Parshall flume) and flow through an opening are not worked out here. For flow through a hole or a nozzle, use the Orifice Flow Calculator.
  • The results are arithmetic for the values you type. This is not professional advice.

Related pages