Concentricity Tolerance Worksheet

Work out concentricity or coaxiality from your own readings. Fill in a row for each place you measured: two opposed indicator readings, or a measured centre point. The worksheet gives the error as the diameter of the zone the feature needs, row by row, and checks it against the tolerance on the drawing.

Enter your values

Two indicators on opposite sides of the feature, read at several places while the part sits on its datum axis.

Your values

Leave it empty to get the error only.

Opposed readings

One row for each diameter you measure. Reading A and Reading B are the two indicators on opposite sides. A reading is above zero when the surface is farther from the datum axis than at the zero setting.

This unit is used in every row.

Two numbers on each line: reading A, reading B.

This is off unless you turn it on. Saved entries stay in this browser only. Untick the box to delete them.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Work out the error.

How to use this worksheet

  1. Choose From opposed indicator readings or From measured centre points.
  2. Fill in one row for each place you measured. You can add and remove rows, or paste two columns of numbers from a spreadsheet and choose Read into rows.
  3. Choose the unit of the readings above the rows.
  4. Type the tolerance from the drawing. It is the diameter of the zone. Leave it empty to get the error only.
  5. Choose Work out the error. Then you can print the result, copy it, or download it as a CSV file. To keep the worksheet, save it on this device or download it as a file that you can open here again.

What the worksheet works out

  • Opposed readings. Two indicators touch the feature on opposite sides, and both are set to zero at the same radius from the datum axis. The point halfway between the two surface points is the median point. It lies (A − B) ÷ 2 from the axis, so it needs a round zone with a diameter of |A − B|.
  • Centre points. A centre that is dx and dy away from the datum axis is √(dx² + dy²) from it, and needs a zone with a diameter of 2 × √(dx² + dy²).
  • The error of the feature is the largest zone that any row needs. The feature is inside the tolerance when that zone is not larger than the tolerance.
  • A + B in the first worksheet is the change of the diameter against the zero setting. It shows a size or form error.
  • The mean offset in the second worksheet shows whether the whole feature is shifted from the datum axis.

Worked example

Opposed readings. At 0° and 180° the indicators read +0.012 mm and −0.006 mm. The median point is (0.012 − (−0.006)) ÷ 2 = 0.009 mm from the axis, and needs a zone of 0.018 mm. The other three rows need 0.012, 0.001 and 0.012 mm. So the concentricity error is 0.018 mm. With a tolerance of 0.02 mm the feature is inside, and it uses 90% of the tolerance.

Centre points. A section has its centre at X 0.006, Y 0.008 mm from the datum axis. That is √(0.006² + 0.008²) = 0.01 mm from the axis, so the section needs a zone of 0.02 mm.

Concentricity, coaxiality and runout

  • Concentricity and coaxiality are about centres only. A feature can be out of round and still be concentric.
  • Runout is what one indicator shows while the part turns on its datum axis. It holds the offset of the centre and the form error of the surface together. A feature with a runout inside a value also has its centres inside a zone of that value, but the other way round is not true.
  • ISO 1101 uses concentricity for the centre of one section and coaxiality for a whole axis. ASME Y14.5 defined concentricity by median points up to its 2009 edition. Its 2018 edition no longer has the concentricity symbol: position or runout is used there instead.
  • Read the drawing and the standard it names before you choose how to measure.

Where the neighbouring jobs are

Limits you should know

  • The result is only as good as the set-up. The part must sit on its datum axis, and the two indicators must be set to zero at the same radius.
  • The worksheet uses the places you measured. A real check needs enough places around and along the feature. The worksheet cannot know what lies between them.
  • It does not fit a best axis through the centres, and it does not work out roundness, cylindricity or runout.
  • It does not accept or reject a part. The measurement uncertainty counts, and a trained person decides.
  • Your rows stay in this browser tab unless you choose to save them on this device or download them as a file.