Works on this device
Expanded Uncertainty Calculator
Multiply a combined standard uncertainty by a coverage factor to get the expanded uncertainty U. Type the factor yourself, or let the page find it for a level of confidence and the degrees of freedom. You can also go back from U to a standard uncertainty.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Expanded uncertainty from a combined standard uncertainty and type the combined standard uncertainty.
- Choose where the coverage factor comes from: a factor that you type, such as 2, or a level of confidence, such as 95%.
- For Student’s t, type the degrees of freedom. For a result from n readings alone this is n − 1.
- Choose Calculate. Type a measured value as well to get the result written as value ± U.
- The other calculations go back from U to a standard uncertainty, find a coverage factor or a level of confidence alone, or work out the effective degrees of freedom of several components.
The formulas
- Expanded uncertainty U = k × u_c. Standard uncertainty u = U ÷ k.
- Coverage factor for a level of confidence p: the value k for which the share of the distribution between −k and +k is p. The page finds it for the normal distribution and for Student’s t distribution.
- Normal distribution: k = 1 covers about 68.27%, k = 1.96 covers 95%, k = 2 about 95.45%, k = 2.576 covers 99% and k = 3 about 99.73%.
- Student’s t gives a larger factor when the uncertainty rests on few readings. For 95% it is 2.262 at 9 degrees of freedom and 12.71 at 1.
- Effective degrees of freedom = u_c⁴ ÷ sum of (contribution⁴ ÷ degrees of freedom of that component). This is the Welch-Satterthwaite formula. A component without a number counts as infinite.
Worked example
A combined standard uncertainty is 0.0038 mm. With k = 2 the expanded uncertainty is 2 × 0.0038 = 0.0076 mm, at a level of confidence of about 95.45% for a normal distribution. A measured value of 10.017 mm is then written as 10.0170 ± 0.0076 mm (k = 2).
If the same uncertainty rests on 10 readings alone, it has 9 degrees of freedom. For 95% the t factor is 2.262, so U = 2.262 × 0.0038 = 0.0086 mm.
Three components of 0.003 (9 degrees of freedom), 0.002 and 0.0012 combine to 0.0038. The effective degrees of freedom are 0.0038⁴ ÷ (0.003⁴ ÷ 9) = 23.17, rounded down to 23. For 95.45% the t factor is 2.115 and U = 0.0080.
Where the neighbouring jobs are
- Combining components into u_c, also with correlation: Combined Uncertainty Calculator.
- The whole evaluation from readings and components: Measurement Uncertainty Calculator.
- The standard deviation of repeated readings: Repeatability Calculator.
Limits you should know
- The level of confidence is true only when the result is spread like a normal or a t distribution. One large rectangular component can make the real level differ.
- Degrees of freedom that are not whole are rounded down, and never below 1. Above 1,000,000 the normal distribution is used.
- The level of confidence must be from 1% to 99.9999%.
- The Welch-Satterthwaite formula is for components that do not depend on each other.
- The results can be downloaded as a CSV file that a spreadsheet opens. The page does not make a spreadsheet with formulas.
- This is arithmetic, not professional advice. It does not replace a written procedure or an accredited laboratory.