Works on this device
Measurement Uncertainty Calculator
Find the uncertainty of a measured value step by step. Type your repeated readings, add the other things that make the result uncertain, such as the calibration and the resolution of the instrument, and get the result written as value ± expanded uncertainty.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose From repeated readings and other components when you have several readings of the same thing. Type them in the rows, or paste a column from a spreadsheet and choose Read into rows.
- Say whether the result is the mean of these readings or one other reading.
- Add one row for each other component. Type its value, choose how the value is given, and for a certificate value type its coverage factor k.
- Choose the coverage factor for the expanded uncertainty, then choose Calculate.
- Choose From components only when the scatter is already a number, or when you have no readings to type.
The method
- Type A is the part you get from statistics. Mean = sum of the readings ÷ n. Sample standard deviation s = √(sum of (reading − mean)² ÷ (n − 1)). For a mean the standard uncertainty is s ÷ √n. For one reading it is s. It has n − 1 degrees of freedom.
- Type B is every other part: a certificate, a limit from a data sheet, the resolution. Each value is divided by the divisor of its distribution to get a standard uncertainty.
- Divisors: the stated coverage factor k for a normal value from a certificate, √3 for the half-width of a rectangular distribution, √6 for a triangular one, √2 for a U-shaped one, and √12 for the full step of a resolution.
- Sensitivity coefficient: how much the result changes for one unit of the input. Contribution = sensitivity coefficient × standard uncertainty.
- Combined standard uncertainty u_c = √(sum of the squared contributions), for inputs that do not depend on each other.
- Effective degrees of freedom = u_c⁴ ÷ sum of (contribution⁴ ÷ degrees of freedom). This is the Welch-Satterthwaite formula.
- Expanded uncertainty U = k × u_c. The coverage factor k is the Student t value for the level of confidence at the effective degrees of freedom, rounded down to a whole number, or a fixed 2 or 3.
- Rounding: in the written result the uncertainty has two significant digits, rounded half away from zero, and the value is rounded to the same decimal place.
Worked example
Ten readings of a length in millimetres: 10.02, 10.01, 10.03, 10.02, 10.00, 10.02, 10.01, 10.03, 10.02, 10.01. The mean is 10.017 mm and s is 0.0095 mm. Type A standard uncertainty of the mean = 0.0095 ÷ √10 = 0.003 mm, with 9 degrees of freedom.
Three other components: a certificate value of 0.004 mm with k = 2 gives 0.004 ÷ 2 = 0.002 mm. A display step of 0.001 mm gives 0.001 ÷ √12 = 0.00029 mm. A temperature limit of ± 0.002 mm gives 0.002 ÷ √3 = 0.00115 mm.
u_c = √(0.003² + 0.002² + 0.00029² + 0.00115²) = 0.0038 mm. The effective degrees of freedom are 23.09, so k for 95.45% is 2.11 and U = 2.11 × 0.0038 = 0.0080 mm. The result is 10.0170 ± 0.0080 mm.
Uncertainty, accuracy and precision
- Precision says how close repeated readings are to each other. The Type A part measures it.
- Accuracy says how close a result is to the true value. A known error (bias) should be corrected first. What is left of it is a Type B component.
- Uncertainty is one number for both: the range around the result where the true value is expected to be, with a stated level of confidence.
Other tools for parts of this job
- Standard uncertainties that you already have, also with correlation between inputs: Combined Uncertainty Calculator.
- Coverage factors, levels of confidence and effective degrees of freedom alone: Expanded Uncertainty Calculator.
- The budget of one calibration point: Calibration Uncertainty Calculator.
- The scatter of readings alone, with a repeatability limit: Repeatability Calculator.
- A result that comes from a formula of several measured values: Error Propagation Calculator.
Limits you should know
- The inputs are taken as independent, and the propagation is first-order. Inputs that depend on each other need a correlation term.
- The coverage factor from Student’s t assumes that the result is spread like a normal or a t distribution. One large rectangular component can make this untrue.
- Above 1,000,000 degrees of freedom the normal distribution is used.
- The calculator cannot find a component that you did not type. A missing component makes the uncertainty too small.
- This is arithmetic, not professional advice. It does not replace a written procedure or an accredited laboratory.