Toolvito

Works on this device

Instrument Resolution Calculator

The smallest step that an instrument shows limits how well you can read it. Work out the standard uncertainty that comes from that step, check whether the step is fine enough for a tolerance, or find the counts and digits that a display needs for a range.

Enter your values

How much uncertainty a display step or a scale division adds to a reading.

Your values

The smallest change that the display shows, or the distance between two marks of the scale, in the unit of the reading.

A scale with wide divisions and a fine pointer can be read between the marks. Choose only what you can really tell apart.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Standard uncertainty from the resolution. Type one display step, or the distance between two marks of the scale.
  2. Say how finely you read the instrument. A digital display is read to the nearest step. A scale can sometimes be read to half a division or finer.
  3. Choose the spread of the reading error and whether the result is one reading or the difference of two.
  4. Choose Calculate.
  5. For a tolerance check, choose Resolution against a tolerance. For a display, choose Display digits and counts for a range.

The formulas

  • Half-width a = half of the smallest step that you read. The true value can be anywhere from a below the reading to a above it.
  • Rectangular distribution: standard uncertainty = a ÷ √3. This is the same as the full step ÷ √12.
  • Triangular distribution: standard uncertainty = a ÷ √6.
  • Two readings: a difference of two readings has √2 × the standard uncertainty of one reading.
  • Half-division rule of school courses: the uncertainty of a reading is taken as plus and minus half of the smallest division, and two readings add.
  • Tolerance ratio = width of the tolerance ÷ resolution.
  • Counts needed = largest value to show ÷ resolution, rounded up.

Worked example

A digital caliper shows steps of 0.01 mm. The half-width is 0.005 mm, and the standard uncertainty is 0.005 ÷ √3 = 0.0029 mm. That is 0.01 ÷ √12.

A ruler has marks every 1 mm and both ends of the object are read. By the school rule the uncertainty is 0.5 + 0.5 = 1 mm. As a standard uncertainty, each end has 0.5 ÷ √3 = 0.29 mm, and the two combine to √2 × 0.29 = 0.41 mm.

A tolerance of plus and minus 0.05 mm has a width of 0.1 mm. With steps of 0.01 mm the ratio is 0.1 ÷ 0.01 = 10 to 1.

A display must show up to 150 with steps of 0.01. It needs 150 ÷ 0.01 = 15,000 counts. That is 5 full digits, or a 4½ digit display, which counts to 19,999.

Rectangular, triangular or the half-division rule

  • Use the rectangular distribution for a digital display, and whenever you only know that the value is somewhere inside the band. It is the usual choice in an uncertainty budget.
  • Use the triangular distribution only when values near the middle of the band are more likely than values near its edges, for example when you estimate by eye between two marks and are rarely far off.
  • The half-division rule gives a limit, not a standard uncertainty. It is the rule of many school courses. In an uncertainty budget that limit is divided by √3.

Limits you should know

  • Resolution is not accuracy. An instrument can show many digits and still be wrong by several steps. Its calibration tells you how far.
  • Resolution is one component of an uncertainty. The Measurement Uncertainty Calculator combines it with the others, and the Calibration Uncertainty Calculator does this for a calibration.
  • The ratio of 10 to 1 is a guideline that you can change. The Measurement System Analysis Calculator also compares the resolution with the spread of a process.
  • A half digit means a first digit of 0 or 1. Makers also sell displays with other counts, so compare the counts.
  • This is arithmetic, not professional advice.