Toolvito

Works on this device

Transmittance to Absorbance Calculator

Convert transmittance (%T or T) to absorbance, or absorbance to transmittance. Type one value or a whole list. You can also start from the two light readings, I and I0.

Enter your values

Turn %T or T readings into absorbance. Type one value or a whole list.

Your values

%T is the fraction T times 100. A reading of 45.2% is the fraction 0.452.

One or more values, separated by commas, spaces or new lines.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Convert.

How to use this calculator

  1. Choose Transmittance to absorbance, Absorbance to transmittance, or light readings if you have the detector values I and I0.
  2. For transmittance, choose whether your values are percents (%T, such as 45.2) or fractions (T, such as 0.452).
  3. Type one value or a list separated by commas. Choose Convert. The table shows T, %T and A for every value, and you can download it as a CSV file.

The formulas

Transmittance is the share of the light that passes through the sample: T = I ÷ I0, where I is the light through the sample and I0 the light through the blank. As a percent, %T = 100 × T.

Absorbance is A = −log10 T. With a percent, the same formula is A = 2 − log10(%T). The other way round, T = 10^(−A) and %T = 100 × 10^(−A).

Absorbance has no unit. Each step of 1 in absorbance means ten times less light: A = 1 is 10% T, A = 2 is 1% T and A = 3 is 0.1% T.

Some values of transmittance and absorbance
%T T A
100% 1 0
50% 0.5 0.301
10% 0.1 1
1% 0.01 2
0.1% 0.001 3

Worked examples

Percent to absorbance. A reading of 45.2% T gives A = 2 − log10(45.2) = 2 − 1.655138 = 0.344862. A reading of 85% T gives A = 0.070581.

Absorbance to percent. An absorbance of 0.345 gives T = 10^(−0.345) = 0.451856, so 45.1856% of the light passes. An absorbance of 0.05 gives 89.1251% T.

Light readings. With I = 452 and I0 = 1,000, T = 0.452 and A = log10(1,000 ÷ 452) = 0.344862.

Limits you should know

  • Absorbance and transmittance are linked by the formula alone; the tool needs no other value. To go from a concentration to an absorbance, use the Beer Lambert Calculator, which shows T beside A. To read concentrations from standards, use the Absorbance to Concentration Calculator.
  • 100 − %T is the light that does not reach the detector. It is not the absorbance, and it also holds light that is reflected or scattered.
  • Above an absorbance of about 2, less than 1% of the light passes, and stray light makes the reading unreliable. Dilute the sample or use a shorter cuvette.
  • A transmittance above 100% gives a negative absorbance. Near zero this is reading noise; larger values point to a wrong blank. The tool takes absorbances from −1 to 10.

Related tools