Works on this device
Microscope Field of View Calculator
Find the width of the circle you see in a microscope, from the field number of the eyepiece and the objective. You can also work out the area a camera records, the field at another magnification, and estimate the size of a cell.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out, for example Field of view through the eyepiece.
- Type the field number of the eyepiece. It is printed after the magnification, such as 10×/20: the 20 is the field number in millimetres. If your eyepiece has no field number, measure the field once (see below).
- Type the objective magnification, such as 10×. Leave the tube factor at 1 unless your head or a magnification changer has a factor.
- Choose Calculate. Switch the result between millimetres and micrometres with its unit menu.
The formulas
- Field of view through the eyepiece = field number ÷ (objective magnification × tube factor). The eyepiece magnification is not part of it.
- Field of a camera = sensor width (or height) ÷ (objective magnification × camera adapter magnification). A sensor of 2448 pixels of 3.45 µm is 2448 × 3.45 µm = 8.4456 mm wide.
- Field at another magnification = the field you measured × the magnification you measured it at ÷ the new magnification.
- Estimated size of an object = field of view ÷ the number of objects that fit across it.
- Area of the field = π × diameter² ÷ 4.
How to measure the field without a field number
- Put a clear ruler or a stage micrometer on the stage and focus at low power, such as with the 4× objective.
- Read how many millimetres fit across the middle of the circle, for example 4.5 mm.
- Choose Field at another magnification. Type 4.5 mm, the low magnification, and the higher magnification you want. A ruler is too coarse at high power, so work those fields out from the low-power one.
Worked example
An eyepiece marked 10×/20 and a 10× objective give a field of 20 ÷ 10 = 2 mm (2,000 µm). With the 40× objective it is 20 ÷ 40 = 0.5 mm (500 µm).
You measured 4.5 mm at 40× total magnification. At 400× the field is 4.5 × 40 ÷ 400 = 0.45 mm. If 5 cells fit across it, one cell is about 450 µm ÷ 5 = 90 µm long.
A camera with an 8.8 × 6.6 mm sensor on a 20× objective with a 0.5× adapter has a magnification of 10× at the camera. It records 8.8 ÷ 10 = 0.88 mm by 6.6 ÷ 10 = 0.66 mm of the specimen.
Limits you should know
- The field number and the camera sizes come from your own eyepiece and camera. The values offered by Try an example are examples only.
- The field by field number is the field of the eyepiece. Some objectives do not light or correct the whole of a wide field, so the edge may be dark or soft.
- An estimate from the field is rough. For a measurement, use an eyepiece scale calibrated with a stage micrometer in the Microscope Calibration Calculator.
- For the total magnification, use the Microscope Magnification Calculator.