Works on this device
Dew Point Calculator
The dew point is the temperature to which air must cool for its water vapour to start to condense. Enter the air temperature and the relative humidity, and get the dew point with the working, a table and a chart.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose the button below them.
Your result
How it was worked out
How to use this calculator
- Choose what you want to calculate. The first choice works from the air temperature and the relative humidity.
- Enter the readings and pick a unit for each one: °C, °F or K.
- Choose Calculate. The result shows the dew point, the spread between temperature and dew point, and the vapour pressure.
- Below 0 °C the result also shows the frost point, which is the value over ice.
- For a printed chart, choose Dew point chart and set the range of temperatures. You can download the table as a CSV file or print it.
The formulas
- Vapour pressure: e = RH ÷ 100 × es(t). es is the saturation vapour pressure at the air temperature t.
- Saturation vapour pressure (Buck equation, 1996): es = 6.1121 × exp((18.678 − t ÷ 234.5) × t ÷ (257.14 + t)) hPa, with t in °C.
- Dew point: the temperature at which es equals e. With s = ln(e ÷ 6.1121) and u = 18.678 − s, td = 2 × 257.14 × s ÷ (u + √(u² − 4 × 257.14 × s ÷ 234.5)). This is the Buck equation turned round.
- Frost point: the same with the ice form, ei = 6.1115 × exp((23.036 − t ÷ 333.7) × t ÷ (279.82 + t)) hPa.
- From wet and dry bulbs: e = es(tw) − A × p × (t − tw), with A = 0.000662 per kelvin for a ventilated psychrometer.
- Pressure dew point: e₂ = e₁ × p₂ ÷ p₁ with absolute pressures. The share of water vapour in the gas does not change when it is compressed or expanded.
- On a surface: water forms when the surface is at or below the dew point. The relative humidity at the surface is e ÷ es(surface temperature) × 100.
Worked examples
Air at 25 °C and 50% relative humidity: es = 31.685 hPa, so e = 15.843 hPa. The dew point is 13.9 °C, and the spread is 11.1 °C.
Air at −5 °C and 60%: the dew point is −11.6 °C and the frost point is −10.3 °C. Frost starts to form on a surface at the frost point.
A compressed air dryer gives a pressure dew point of 3 °C at 7 bar gauge. The absolute pressures are 8.01325 bar and 1.01325 bar, so the vapour pressure falls from 7.5801 hPa to 0.95848 hPa. In the open air the dew point of that air is −23.1 °C (frost point −20.8 °C).
A room is at 25 °C and 50%. A window pane at 12 °C is 1.9 °C below the dew point, so water forms on it. On that pane condensation starts when the room humidity passes 44.3%.
Dew point comfort guide
The US National Weather Service gives this general guide for warm weather. A dew point at or below 55 °F (12.8 °C) feels dry and comfortable. Between 55 and 65 °F (12.8 and 18.3 °C) the air becomes sticky, with muggy evenings. At or above 65 °F (18.3 °C) there is a lot of moisture in the air and it becomes oppressive.
This is a guide to how the air feels to most people. It is not health advice.
Pages for the jobs next to this one
- Relative humidity from temperature and dew point: Relative Humidity Calculator.
- The wet-bulb temperature from a dew point: Wet Bulb Calculator.
- The height of the cloud base from temperature and dew point: Cloud Base Calculator.
- Enthalpy, air density and every other property of moist air: Psychrometric Calculator.
Limits you should know
- The Buck equation is given by its author for −80 to 50 °C. From 0 to 100 °C it is within about 0.1% of the older Goff and Gratch formula. Dew points below −40 °C over liquid water are rough.
- The pressure dew point treats the gas as ideal. At 10 bar the real-gas correction is a few percent in vapour pressure, which is a few tenths of a degree in the dew point.
- The surface check is for the surface itself. It does not find where the dew point falls inside a wall. That needs the layers of the wall and their thermal resistance.
- The margin of 3 °C above the dew point is common on paint and coating data sheets. Use the value on your product data sheet.
- The mould level of 80% at a surface comes from ISO 13788. It is a guide and not an assessment of a building.
- This tool works with water vapour. It does not find the dew point of natural gas, carbon dioxide or other gases.
- This page uses the readings you type. It does not fetch weather data and it is not a forecast.