Wet Bulb Calculator

The wet-bulb temperature is what a thermometer reads when its bulb is kept wet and air moves past it. Enter the air temperature and the humidity to get it, or enter wet and dry bulb readings to get the humidity.

Enter your values

Use this with the air temperature and humidity of a weather report or a room sensor.

Your values

The air pressure at your place, not the pressure reduced to sea level. Leave it empty to use the standard atmosphere for the height below.

Used only when the pressure is empty. The standard atmosphere gives the pressure for this height.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to calculate. The first choice gives the wet-bulb temperature from the air temperature and the relative humidity.
  2. Enter the values and pick a unit for each temperature: °C, °F or K.
  3. Enter the pressure at your place, or leave it empty and enter your height above sea level. The wet bulb depends on the pressure.
  4. Choose Calculate. The result shows the wet-bulb temperature, the depression below the air temperature, and a table for other values of humidity.
  5. For a sling psychrometer, choose Humidity and dew point from dry-bulb and wet-bulb readings.

The formulas

  • Psychrometer relation: e = es(tw) − A × p × (t − tw). Here e is the vapour pressure, tw the wet-bulb temperature, t the air temperature and p the air pressure. A is 0.000662 per kelvin for a ventilated psychrometer.
  • Wet-bulb temperature: the value of tw that makes the relation true. There is no direct formula for it, so the page finds it by halving an interval many times.
  • Saturation vapour pressure (Buck equation, 1996): es = 6.1121 × exp((18.678 − t ÷ 234.5) × t ÷ (257.14 + t)) hPa, with t in °C.
  • Quick estimate (Stull, 2011): tw = t × atan(0.151977 × √(RH + 8.313659)) + atan(t + RH) − atan(RH − 1.676331) + 0.00391838 × RH^1.5 × atan(0.023101 × RH) − 4.686035. It needs no pressure and is made for sea level.
  • Wet-bulb globe temperature (ISO 7243): 0.7 × natural wet bulb + 0.2 × globe + 0.1 × air temperature in the sun, and 0.7 × natural wet bulb + 0.3 × globe without sun.

Worked examples

Air at 25 °C and 50% relative humidity at 1013.25 hPa: es = 31.685 hPa and e = 15.843 hPa. The relation is true for tw = 17.9 °C, because 20.573 − 0.000662 × 1013.25 × (25 − 17.949) = 15.843 hPa. The Stull estimate gives 18.0 °C.

A psychrometer reads 25 °C dry and 18 °C wet at 1013.25 hPa. e = 20.639 − 0.000662 × 1013.25 × 7 = 15.944 hPa, so the relative humidity is 50.3% and the dew point is 14.0 °C.

A WBGT instrument in the sun reads 25 °C natural wet bulb, 40 °C globe and 32 °C air. WBGT = 0.7 × 25 + 0.2 × 40 + 0.1 × 32 = 28.7 °C.

Two kinds of wet bulb

The wet bulb of a psychrometer is ventilated: air moves past the wet wick at a few metres per second. The first four options on this page are for that wet bulb.

The natural wet bulb of a WBGT instrument stands in the open with no fan and no shield, so the sun and the wind change its reading. It is a different measurement. Do not put a psychrometer reading or a value from the first option into the WBGT option.

Pages for the jobs next to this one

Limits you should know

  • The psychrometer coefficient 0.000662 per kelvin is for a ventilated wet bulb. In still air a wet bulb reads higher.
  • The thermodynamic wet-bulb temperature of the ASHRAE handbook is defined in another way. It differs from the value here by less than 0.3 °C between 0 and 50 °C.
  • The Stull estimate is for 1013.25 hPa, a relative humidity of 5% to 99% and −20 to 50 °C. From 0 to 50 °C and 10% to 99% it is within about 1 °C of the full solution. It is weakest in cold, dry air.
  • Below 0 °C the wick of a real wet bulb may freeze. The page takes the wick as wet with liquid water.
  • The pressure from a height uses the standard atmosphere (ISO 2533). A measured station pressure is better.
  • The WBGT option adds up your three readings with the weights of ISO 7243. It does not estimate WBGT from weather data, and it is not a heat-safety ruling. This page does not give medical advice.