Works on this device
Thermal Efficiency Calculator
Work out the thermal efficiency of a heat engine from its work and heat, of a power plant or gas turbine from its power and fuel, or of a heater from the heat it gives a fluid. You can also turn an efficiency into a heat rate and back.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose a heat engine, a power plant on fuel, the heat rate converter, or a heating device.
- For a heat engine, choose which two values you know: work, heat input, heat rejected or efficiency, as power or as energy.
- For a plant or a heater, enter the fuel as a heat input, or as a flow with your heating value (net or gross). No fuel figure is built in.
- Choose Calculate. The result shows the efficiency, the other values, the heat rate where it applies, and the working.
The formulas
- Heat engine: η = W ÷ Qin = 1 − Qout ÷ Qin, because Qin = W + Qout.
- Plant on fuel: η = net power ÷ (fuel flow × heating value).
- Heat rate: 3,600 kJ/kWh ÷ η = 3,412.14 BTU/kWh ÷ η = 859.845 kcal/kWh ÷ η.
- Heating device: η = useful heat ÷ heat input, with useful heat = ṁ × cp × (Tout − Tin) for a heated fluid.
Worked examples
A heat engine takes in 100 kW of heat and gives 40 kW of work: η = 40 ÷ 100 = 40%, and it rejects 60 kW.
A gas turbine gives 100 MW from 20 t/h of fuel with an example heating value of 50 MJ/kg (net). The fuel heat input is 20,000 ÷ 3,600 × 50 = 277.778 MW, so η = 100 ÷ 277.778 = 36% and the heat rate is 3,600 ÷ 0.36 = 10,000 kJ/kWh (9,478.17 BTU/kWh).
A heat rate of 9,000 kJ/kWh means η = 3,600 ÷ 9,000 = 40%.
A heater warms 40 m³/h of water (1,000 kg/m³, 4.186 kJ/(kg·K)) from 60 °C to 80 °C: the useful heat is 40 ÷ 3,600 × 1,000 × 4.186 × 20 = 930.222 kW. With 1,000 kW of fuel heat in, η = 93.0222%.
Limits you should know
- The efficiency carries the basis of your figures: net (LHV) or gross (HHV) heating value, gross or net power. Compare plants only on the same basis.
- The heating values in the examples are only for trying the tool. Use the figure from your fuel supplier or a lab test.
- No heat engine can beat the Carnot efficiency between its hot and cold temperatures: see the Carnot Efficiency Calculator.
- For steam boilers (steam enthalpies, the losses method and flue gas checks), use the Boiler Efficiency Calculator. For the heat to warm a material or an air flow, see the Sensible Heat Calculator.
- Isentropic efficiency of a turbine or a compressor (with steam or gas tables) is a different figure and is not worked out here.
- This is arithmetic for learning and checking, not an acceptance test.