Works on this device
Carnot Efficiency Calculator
No heat engine can turn all its heat into work, and the Carnot efficiency is the upper limit set by two temperatures. Find it for an engine, or find the highest coefficient of performance of a refrigerator or a heat pump.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the machine: a heat engine, a refrigerator (or air conditioner), or a heat pump.
- Choose what you want to find: the Carnot efficiency or COP, or one of the two temperatures for a value you want.
- Enter the temperatures in °C, K or °F. The tool works in kelvin, which these formulas need.
- Optional: enter a heat or power to get the most work or the least power needed, and the value of a real machine to compare it with the limit.
The formulas
- Heat engine: η = 1 − T_c ÷ T_h = (T_h − T_c) ÷ T_h. The most work from heat Q_h is W = η × Q_h.
- Refrigerator: COP_R = T_c ÷ (T_h − T_c). The least work to take heat Q_c out of the cold space is W = Q_c ÷ COP_R.
- Heat pump: COP_HP = T_h ÷ (T_h − T_c) = COP_R + 1. The least work to deliver heat Q_h is W = Q_h ÷ COP_HP.
- T_h and T_c are the absolute temperatures (kelvin) of the hot and the cold side. Turned round, for example, T_c = T_h × (1 − η).
Worked examples
A steam engine between 500 °C (773.15 K) and 25 °C (298.15 K): η = 1 − 298.15 ÷ 773.15 = 0.6144, which is 61.44%. Using °C directly (1 − 25 ÷ 500 = 95%) would be wrong.
An engine between 600 K and 300 K has η = 50%. From 100 kW of heat it can give at most 50 kW of work, and must give off at least 50 kW to the cold side.
A fridge between −5 °C inside and 35 °C outside: COP = 268.15 ÷ 40 = 6.70. A heat pump between 0 °C outside and 35 °C water: COP = 308.15 ÷ 35 = 8.80.
Limits you should know
- These values are the upper limits of the second law of thermodynamics. No real engine, refrigerator or heat pump reaches them, because of friction, heat flow across real temperature differences and other losses.
- The temperatures are those of the two reservoirs. In a real machine the working fluid must be colder than the heat source and warmer than the heat sink, so the useful limit is lower still.
- The rated COP, EER or SCOP of a real air conditioner or heat pump comes from tests under set conditions and is not a Carnot value. For sizing a heat pump, see the Heat Pump Sizing Calculator; for the efficiency of a real plant, the Thermal Efficiency Calculator.